Notifications
You must be signed in to change notification settings - Fork 8
Configuration toml
Stefan Allius edited this page Apr 9, 2025
·
4 revisions
The proxy can be configured via the file 'config.toml'. When the proxy is started, a file 'config.example.toml' is copied into the config directory. This file shows all possible parameters and their default values. Changes in the example file itself are not evaluated. To configure the proxy, the config.example.toml file should be renamed to config.toml. After that the corresponding values can be adjusted. To load the new configuration, the proxy must be restarted.
The configration uses the TOML format, which aims to be easy to read due to obvious semantics. You find more details here: https://toml.io/en/v1.0.0
The available keywords are defined here: Configuration
Example of a full config.toml file:
##########################################################################################
###
### T S U N - G E N 3 - P R O X Y
###
### from Stefan Allius
###
##########################################################################################
###
### The readme will give you an overview of the project:
### https://s-allius.github.io/tsun-gen3-proxy/
###
### The proxy supports different operation modes. Select the proper mode
### which depends on your inverter type and you inverter firmware.
### Please read:
### https://github.com/s-allius/tsun-gen3-proxy/wiki/Operation-Modes-Overview
###
### Here you will find a description of all configuration options:
### https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml
###
### The configration uses the TOML format, which aims to be easy to read due to
### obvious semantics. You find more details here: https://toml.io/en/v1.0.0
###
##########################################################################################
##########################################################################################
##
## MQTT broker configuration
##
## In this block, you must configure the connection to your MQTT broker and specify the
## required credentials. As the proxy does not currently support an encrypted connection
## to the MQTT broker, it is strongly recommended that you do not use a public broker.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#mqtt-broker-account
##
mqtt.host = 'mqtt' # URL or IP address of the mqtt broker
mqtt.port = 1883
mqtt.user = ''
mqtt.passwd = ''
##########################################################################################
##
## HOME ASSISTANT
##
## The proxy supports the MQTT autoconfiguration of Home Assistant (HA). The default
## values match the HA default configuration. If you need to change these or want to use
## a different MQTT client, you can adjust the prefixes of the MQTT topics below.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#home-assistant
##
ha.auto_conf_prefix = 'homeassistant' # MQTT prefix for subscribing for homeassistant status updates
ha.discovery_prefix = 'homeassistant' # MQTT prefix for discovery topic
ha.entity_prefix = 'tsun' # MQTT topic prefix for publishing inverter values
ha.proxy_node_id = 'proxy' # MQTT node id, for the proxy_node_id
ha.proxy_unique_id = 'P170000000000001' # MQTT unique id, to identify a proxy instance
##########################################################################################
##
## GEN3 Proxy Mode Configuration
##
## In this block, you can configure an optional connection to the TSUN cloud for GEN3
## inverters. This connection is only required if you want send data to the TSUN cloud
## to use the TSUN APPs or receive firmware updates.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#tsun-cloud-for-gen3-inverter-only
##
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
tsun.host = 'logger.talent-monitoring.com'
tsun.port = 5005
##########################################################################################
##
## GEN3PLUS Proxy Mode Configuration
##
## In this block, you can configure an optional connection to the TSUN cloud for GEN3PLUS
## inverters. This connection is only required if you want send data to the TSUN cloud
## to use the TSUN APPs or receive firmware updates.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#solarman-cloud-for-gen3plus-inverter-only
##
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
solarman.host = 'iot.talent-monitoring.com'
solarman.port = 10000
##########################################################################################
###
### Inverter Definitions
###
### The proxy supports the simultaneous operation of several inverters, even of different
### types. A configuration block must be defined for each inverter, in which all necessary
### parameters must be specified. These depend on the operation mode used and also differ
### slightly depending on the inverter type.
###
### In addition, the PV modules can be defined at the individual inputs for documentation
### purposes, whereby these are displayed in Home Assistant.
###
### The proxy only accepts connections from known inverters. This can be switched off for
### test purposes and unknown serial numbers are also accepted.
###
inverters.allow_all = false # only allow known inverters
##########################################################################################
##
## For each GEN3 inverter, the serial number of the inverter must be mapped to an MQTT
## definition. To do this, the corresponding configuration block is started with
## `[Inverter.“<16-digit serial number>”]` so that all subsequent parameters are assigned
## to this inverter. Further inverter-specific parameters (e.g. polling mode) can be set
## in the configuration block
##
## The serial numbers of all GEN3 inverters start with `R17`!
##
[inverters."R17xxxxxxxxxxxx1"]
node_id = 'inv_1' # MQTT replacement for inverters serial number
suggested_area = 'roof' # suggested installation place for home-assistant
modbus_polling = false # Disable optional MODBUS polling for GEN3 inverter
pv1 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
pv2 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
##########################################################################################
##
## For each GEN3PLUS inverter, the serial number of the inverter must be mapped to an MQTT
## definition. To do this, the corresponding configuration block is started with
## `[Inverter.“<16-digit serial number>”]` so that all subsequent parameters are assigned
## to this inverter. Further inverter-specific parameters (e.g. polling mode, client mode)
## can be set in the configuration block
##
## The serial numbers of all GEN3PLUS inverters start with `Y17` or Y47! Each GEN3PLUS
## inverter is supplied with a “Monitoring SN:”. This can be found on a sticker enclosed
## with the inverter.
##
[inverters."Y17xxxxxxxxxxxx1"] # This block is also for inverters with a Y47 serial no
monitor_sn = 2000000000 # The GEN3PLUS "Monitoring SN:"
node_id = 'inv_2' # MQTT replacement for inverters serial number
suggested_area = 'garage' # suggested installation place for home-assistant
modbus_polling = true # Enable optional MODBUS polling
# if your inverter supports SSL connections you must use the client_mode. Pls, uncomment
# the next line and configure the fixed IP of your inverter
#client_mode = {host = '192.168.0.1', port = 8899, forward = true}
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv4 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
##########################################################################################
##
## For each GEN3PLUS energy storage system, the serial number must be mapped to an MQTT
## definition. To do this, the corresponding configuration block is started with
## `[batteries.“<16-digit serial number>”]` so that all subsequent parameters are assigned
## to this energy storage system. Further device-specific parameters (e.g. polling mode,
## client mode) can be set in the configuration block
##
## The serial numbers of all GEN3PLUS energy storage systems/batteries start with `410`!
## Each GEN3PLUS device is supplied with a “Monitoring SN:”. This can be found on a
## sticker enclosed with the inverter.
##
[batteries."4100000000000001"]
monitor_sn = 3000000000 # The GEN3PLUS "Monitoring SN:"
node_id = 'bat_1' # MQTT replacement for devices serial number
suggested_area = ''garage' # suggested installation place for home-assistant
modbus_polling = true # Enable optional MODBUS polling
# if your inverter supports SSL connections you must use the client_mode. Pls, uncomment
# the next line and configure the fixed IP of your inverter
#client_mode = {host = '192.168.0.1', port = 8899, forward = true}
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
##########################################################################################
###
### If the proxy mode is configured, commands from TSUN can be sent to the inverter via
### this connection or parameters (e.g. network credentials) can be queried. Filters can
### then be configured for the AT+ commands from the TSUN Cloud so that only certain
### accesses are permitted.
###
### An overview of all known AT+ commands can be found here:
### https://github.com/s-allius/tsun-gen3-proxy/wiki/AT--commands
###
[gen3plus.at_acl]
tsun.allow = ['AT+Z', 'AT+UPURL', 'AT+SUPDATE'] # allow this for TSUN access
tsun.block = []
mqtt.allow = ['AT+'] # allow all via mqtt
mqtt.block = []