Expand Up @@ -160,7 +160,7 @@ Inquiry Command
------------------------------------------------

| Computer: ``QPIRI<CRC><cr>``
| Device: ``(BBB.B CC.C DDD.D EE.E FF.F HHHH IIII JJ.J KK.K JJ.J KK.K LL.L O PP QQ 0 O P Q R SS T U VV.V W X YYY Z CCC <CRC><cr>``
| Device: ``(BBB.B CC.C DDD.D EE.E FF.F HHHH IIII JJ.J KK.K JJ.J KK.K LL.L O PP QQQ O P Q R SS T U VV.V W X YYY Z CCC <CRC><cr>``
.. csv-table:: Response Decode
:header: ,Component, Description, Units, Notes
Expand All @@ -181,121 +181,51 @@ Inquiry Command
M, KK.K, Battery bulk voltage, V, K is an Integer ranging from 0 to 9.
N, LL.L, Battery float voltage, V, L is an Integer ranging from 0 to 9.
O, O, Battery type, , "| 0: AGM
| 1: Flooded
| 2: User
| 3: Pylon
| 5: Weco
| 6: Soltaro
| 8: Lib
| 9: Lic"

P PP Max AC charging current

P is an Integer ranging from 0 to 9
The units is A.
If the max AC charging current is
greater than 99A, then return to PPP
Q QQ 0 Max charging current Q^ is an Integer ranging from 0 to 9.
The units is A.

O O Input voltage range
0: Appliance
1: UPS

P P Output source priority

```
0: UtilitySolarBat
1: SolarUtilityBat
2: SolarBatUtility
```
Q Q Charger source priority

1: Solar first
2: Solar + Utility
3: Only solar charging permitted
R R Parallel max num R is an Integer ranging from 0 to 9.

S SS Machine type

```
00: Grid tie;
01: Off Grid;
10: Hybrid.
```
T T Topology
0: transformerless
1: transformer

U U Output mode

```
00: single machine output
01: parallel output
02: Phase 1 of 3 Phase output
03: Phase 2 of 3 Phase output
04: Phase 3 of 3 Phase output
05: Phase 1 of 2 Phase output
06: Phase 2 of 2 Phase output (120°)
07: Phase 2 of 2 Phase output (180°)
```
V VV.V Battery re-discharge voltage

```
V is an Integer ranging from 0 to 9.
The unit is V.
```
W W PV OK condition for parallel 0: As long as one unit of inverters
has connect PV, parallel system will


```
consider PV OK;
1: Only All of inverters have connect
PV, parallel system will consider PV
OK
```
```
X X PV power balance
```
```
0: PV input max current will be the
max charged current;
1: PV input max power will be the
sum of the max charged power and
loads power.
```
```
Y YYY
Max. charging time at C.V
stage (only 48 V model)
```
```
Y is an Integer ranging from 0 to 9.
The unit is minute.
```
#### Z Z

```
Operation Logic (only 48V
model)
```
```
0: Automatically
1: On-line mode
2: ECO mode
```
```
A1 CCC
Max discharging current
(only 48V model)
```
```
C is an integer ranging from 0 to 9.
The units is A.
```
### 2.8 QFLAG<cr>: Device flag status inquiry
| 1: Flooded
| 2: User
| 3: Pylon
| 5: Weco
| 6: Soltaro
| 8: Lib
| 9: Lic"
P, PP, Max AC charging current, A, "P is an Integer ranging from 0 to 9. If the max AC charging current is greater than 99A, then return to PPP"
Q, QQQ, Max charging current, A, Q is an Integer ranging from 0 to 9.
O, O, Input voltage range, , "| 0: Appliance
| 1: UPS"
P, P, Output source priority, , "| 0: UtilitySolarBat
| 1: SolarUtilityBat
| 2: SolarBatUtility"
Q, Q, Charger source priority, , "| 1: Solar first
| 2: Solar + Utility
| 3: Only solar charging permitted"
R, R, Parallel max num, R is an Integer ranging from 0 to 9.
S, SS, Machine type, , "| 00: Grid tie
| 01: Off Grid
| 10: Hybrid"
T, T, Topology, , "| 0: transformerless
| 1: transformer"
U, U, Output mode, , "| 00: single machine output
| 01: parallel output
| 02: Phase 1 of 3 Phase output
| 03: Phase 2 of 3 Phase output
| 04: Phase 3 of 3 Phase output
| 05: Phase 1 of 2 Phase output
| 06: Phase 2 of 2 Phase output (120°)
| 07: Phase 2 of 2 Phase output (180°)"
V, VV.V, Battery re-discharge voltage, V, V is an Integer ranging from 0 to 9.
W, W, PV OK condition for parallel, , "| 0: As long as one unit of inverters has connect PV, parallel system will consider PV OK
| 1: Only All of inverters have connect PV, parallel system will consider PV OK"
X, X, PV power balance, , "| 0: PV input max current will be the max charged current
| 1: PV input max power will be the sum of the max charged power and loads power."
Y, YYY, Max. charging time at C.V stage (only 48 V model), min, Y is an Integer ranging from 0 to 9.
Z, Z, Operation Logic (only 48V model), , "| 0: Automatically
| 1: On-line mode
| 2: ECO mode"
A1, CCC, Max discharging current (only 48V model), A, C is an integer ranging from 0 to 9.


2.8 QFLAG<cr>: Device flag status inquiry
-----------------------------------------

```
ExxxDxxx is the flag status. E means enable, D means disable