Skip to content

Hitachi RD-22FC dehumidifier issue #3

@xangin

Description

@xangin

1. "Air Purifier" 開關無效

打開開關但機器面板上對應的燈並未亮起
Log:

[22:39:11][D][switch:012]: 'Air Purifier' Turning ON.
[22:39:11][D][uart_debug:114]: >>> 06:04:8D:00:01:8E 
[22:39:11][D][switch:055]: 'Air Purifier': Sending state ON 
[22:39:11][D][uart_debug:114]: <<< 06:04:FF:00:01:FC 
[22:39:11][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

[22:43:09][D][switch:016]: 'Air Purifier' Turning OFF. 
[22:43:09][D][uart_debug:114]: >>> 06:04:8D:00:00:8F 
[22:43:09][D][switch:055]: 'Air Purifier': Sending state OFF 
[22:43:09][D][uart_debug:114]: <<< 06:04:FF:00:00:FD 
[22:43:10][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

2. "Auto Air Flow" 開關無效

打開開關但機器面板上對應的燈並未亮起
Log:

[22:39:59][D][switch:012]: 'Auto Air Flow' Turning ON. 
[22:39:59][D][uart_debug:114]: >>> 06:04:88:00:01:8B 
[22:39:59][D][switch:055]: 'Auto Air Flow': Sending state ON 
[22:39:59][D][uart_debug:114]: <<< 06:04:FF:00:01:FC 
[22:39:59][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

[22:42:11][D][switch:016]: 'Auto Air Flow' Turning OFF. 
[22:42:11][D][uart_debug:114]: >>> 06:04:88:00:00:8A 
[22:42:11][D][switch:055]: 'Auto Air Flow': Sending state OFF 
[22:42:11][D][uart_debug:114]: <<< 06:04:FF:00:00:FD 
[22:42:11][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

3. light level顯示是相反的?這是否正常?

0: 最亮
1: 亮
2: 暗
3: 燈光關閉

再請蔥大撥冗查看,或有需要提供其他log再請告知,謝謝。

Activity

tsunglung

tsunglung commented on Jun 22, 2024

@tsunglung
Owner

1,2 點,在 RD-360HS/G 上,都是正常
除溼機,在開機狀態,HA 打開 air purifier 或 auto air flow , 機器上的燈跟著亮。關閉,燈就關。

  1. 燈亮度(0x27) ,在 3.0 時,沒有定義,根據 service code 知道有這個 ID, 嘗試之後,知道它是控制燈亮度,有4階。至於它對應的亮度,0是最亮,或是最暗,這個只是一個定義(enum值)。
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

      Development

      No branches or pull requests

        Participants

        @tsunglung@xangin

        Issue actions

          Hitachi RD-22FC dehumidifier issue · Issue #3 · tsunglung/taixia