| 1 | +--- |
| 2 | +title: "Mirrored M.2 Ordering Examples" |
| 3 | +description: "An explanation of the required settings for ordering a Mirrored M.2 server from the API." |
| 4 | +date: "2025-06-10" |
| 5 | +tags: |
| 6 | + - "article" |
| 7 | + - "sldn" |
| 8 | + - "order" |
| 9 | + - "package" |
| 10 | + - "slcli" |
| 11 | +--- |
| 12 | + |
| 13 | +*NOTE*: This article is for [slcli v6.2.7](https://github.com/softlayer/softlayer-python/releases/tag/v6.2.7) and [ibmcloud sl v1.5.7](https://github.com/softlayer/softlayer-cli/releases/tag/v1.5.7) |
| 14 | + |
| 15 | + |
| 16 | +# Basics |
| 17 | + |
| 18 | +Ordering a server with a mirrored NVMe M.2 boot drive is a little tricky. There are 2 main difference between this setup and a normal order. |
| 19 | + |
| 20 | +1. `storageGroups` need to be defined with the NVMe array first |
| 21 | +2. NVMe array needs to set `hardDriveCategoryCodes` and `diskControllerIndex: 1` |
| 22 | + |
| 23 | +> The `0th` index storageGroup will be what the server boots from. It will not match the order the raid cards are ordered in. |
| 24 | +
|
| 25 | +3. You will need to have DISK_CONTROLLER_RAID (`diskControllerIndex: 0`) in your order, before DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 (`diskControllerIndex: 1`). DISK_CONTROLLER_RAID uses the `disk_controller` category price, and DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 uses `disk_controller1` category price when both are present in an order. |
| 26 | + |
| 27 | +This ordering is important because otherwise the SLCLI will pick the incorrect price id, and you will get one of the errors listed below. |
| 28 | + |
| 29 | +4. A basic order will look like this: |
| 30 | + |
| 31 | +```bash |
| 32 | +./slcli -v order place --verify 2U_DUAL_INTEL_XEON_SAPPHIRE_RAPIDS_FAMILY_16_DRIVES DALLAS13 \ |
| 33 | +--complex-type SoftLayer_Container_Product_Order_Hardware_Server --billing monthly \ |
| 34 | +--extras '{"hardware":[{"hostname":"test1nvme","domain":"ibm.com"}],"storageGroups":[{"arraySize":480,"arrayTypeId":2, "diskControllerIndex":1,"hardDriveCategoryCodes":["secondary_pcie_slot0","secondary_pcie_slot1"]}, {"arraySize":1920,"arrayTypeId":2,"diskControllerIndex": 0,"hardDrives":[0,1]}]}' \ |
| 35 | +AUTOMATED_NOTIFICATION MONITORING_HOST_PING NOTIFICATION_EMAIL_AND_TICKET REBOOT_KVM_OVER_IP \ |
| 36 | +UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT BANDWIDTH_0_GB 1_IP_ADDRESS \ |
| 37 | +1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS DISK_CONTROLLER_RAID \ |
| 38 | +DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 \ |
| 39 | +MIRRORED_NVME_M_2_OS_BOOT_480GB 256_GB_RAM_DDR5 OS_CENTOS_STREAM_9_X_64_BIT \ |
| 40 | +INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70 REDUNDANT_POWER_SUPPLY HARD_DRIVE_1_9_TB_SSD \ |
| 41 | +HARD_DRIVE_1_9_TB_SSD |
| 42 | +``` |
| 43 | + |
| 44 | +```bash |
| 45 | +Calling: SoftLayer_Product_Order::verifyOrder(id=None, mask='', filter='None', args=({'orderContainers': [{ |
| 46 | +'hardware': [{'hostname': 'test1nvme', 'domain': 'ibm.com'}], |
| 47 | +'storageGroups': [ |
| 48 | + { |
| 49 | + 'arraySize': 480,'arrayTypeId': 2, 'diskControllerIndex': 1, |
| 50 | + 'hardDriveCategoryCodes': ['secondary_pcie_slot0', 'secondary_pcie_slot1'] |
| 51 | + },{ |
| 52 | + 'arraySize': 1920, 'arrayTypeId': 2, 'diskControllerIndex': 0, 'hardDrives': [0, 1] |
| 53 | +}], |
| 54 | +'packageId': 3137, |
| 55 | +'quantity': 1, |
| 56 | +'location': 1854895, |
| 57 | +'useHourlyPricing': False, |
| 58 | +'complexType': 'SoftLayer_Container_Product_Order_Hardware_Server', |
| 59 | +'prices': [ |
| 60 | + {'id': 58, 'categories': [{'categoryCode': 'response'}], 'item': {'keyName': 'AUTOMATED_NOTIFICATION'}}, |
| 61 | + {'id': 55, 'categories': [{'categoryCode': 'monitoring'}], 'item': {'keyName': 'MONITORING_HOST_PING'}}, |
| 62 | + {'id': 57, 'categories': [{'categoryCode': 'notification'}], 'item': {'keyName': 'NOTIFICATION_EMAIL_AND_TICKET'}}, |
| 63 | + {'id': 906, 'categories': [{'categoryCode': 'remote_management'}], 'item': {'keyName': 'REBOOT_KVM_OVER_IP'}}, |
| 64 | + {'id': 420, 'categories': [{'categoryCode': 'vpn_management'}], 'item': {'keyName': 'UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT'}}, |
| 65 | + {'id': 22505, 'categories': [{'categoryCode': 'bandwidth'}], 'item': {'keyName': 'BANDWIDTH_0_GB'}}, |
| 66 | + {'id': 21, 'categories': [{'categoryCode': 'pri_ip_addresses'}], 'item': {'keyName': '1_IP_ADDRESS'}}, |
| 67 | + {'id': 14023, 'categories': [{'categoryCode': 'port_speed'}], 'item': {'keyName': '1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS'}}, |
| 68 | + {'id': 22484, 'categories': [{'categoryCode': 'disk_controller'}], 'item': {'keyName': 'DISK_CONTROLLER_RAID'}}, |
| 69 | + {'id': 306531, 'categories': [{'categoryCode': 'disk_controller1'}], 'item': {'keyName': 'DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2'}}, |
| 70 | + {'id': 311834, 'categories': [{'categoryCode': 'pcie_slot0'}], 'item': {'keyName': 'MIRRORED_NVME_M_2_OS_BOOT_480GB'}}, |
| 71 | + {'id': 301502, 'categories': [{'categoryCode': 'ram'}], 'item': {'keyName': '256_GB_RAM_DDR5'}}, |
| 72 | + {'id': 307539, 'categories': [{'categoryCode': 'os'}], 'item': {'keyName': 'OS_CENTOS_STREAM_9_X_64_BIT'}}, |
| 73 | + {'id': 313326, 'categories': [{'categoryCode': 'server'}], 'item': {'keyName': 'INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70'}}, |
| 74 | + {'id': 50221, 'categories': [{'categoryCode': 'power_supply'}], 'item': {'keyName': 'REDUNDANT_POWER_SUPPLY'}}, |
| 75 | + {'id': 300316, 'categories': [{'categoryCode': 'disk0'}], 'item': {'keyName': 'HARD_DRIVE_1_9_TB_SSD'}}, |
| 76 | + {'id': 300316, 'categories': [{'categoryCode': 'disk0'}], 'item': {'keyName': 'HARD_DRIVE_1_9_TB_SSD'}} |
| 77 | +] |
| 78 | +}]}) limit=None, offset=None) |
| 79 | + |
| 80 | +┌─────────────────────────────────────────────────────┬────────────────────────────────────────────────┬──────┐ |
| 81 | +│ keyName │ description │ cost │ |
| 82 | +├─────────────────────────────────────────────────────┼────────────────────────────────────────────────┼──────┤ |
| 83 | +│ AUTOMATED_NOTIFICATION │ Automated Notification │ 0 │ |
| 84 | +│ MONITORING_HOST_PING │ Host Ping │ 0 │ |
| 85 | +│ NOTIFICATION_EMAIL_AND_TICKET │ Email and Ticket │ 0 │ |
| 86 | +│ REBOOT_KVM_OVER_IP │ Reboot / KVM over IP │ 0 │ |
| 87 | +│ UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT │ Unlimited SSL VPN Users │ 0 │ |
| 88 | +│ BANDWIDTH_0_GB │ 0 GB Bandwidth Allotment │ 0 │ |
| 89 | +│ 1_IP_ADDRESS │ 1 IP Address │ 0 │ |
| 90 | +│ 1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS │ 1 Gbps Redundant Private Network Uplinks │ 0 │ |
| 91 | +│ DISK_CONTROLLER_RAID │ RAID │ 0 │ |
| 92 | +│ DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 │ RAID 1 (Mirrored NVMe M.2) │ 0 │ |
| 93 | +│ MIRRORED_NVME_M_2_OS_BOOT_480GB │ Mirrored NVMe M.2 for OS Boot (480GB) │ 0 │ |
| 94 | +│ 256_GB_RAM_DDR5 │ 256 GB RAM │ 0 │ |
| 95 | +│ OS_CENTOS_STREAM_9_X_64_BIT │ CentOS Stream 9.x (64 bit) │ 0 │ |
| 96 | +│ INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70 │ Dual Intel Xeon Gold 6416H (24 Cores, 2.7 GHz) │ 0 │ |
| 97 | +│ REDUNDANT_POWER_SUPPLY │ Redundant Power Supply │ 0 │ |
| 98 | +│ HARD_DRIVE_1_9_TB_SSD │ 1.9TB SSD │ 0 │ |
| 99 | +│ HARD_DRIVE_1_9_TB_SSD │ 1.9TB SSD │ 0 │ |
| 100 | +└─────────────────────────────────────────────────────┴────────────────────────────────────────────────┴──────┘ |
| 101 | +``` |
| 102 | + |
| 103 | +From there you can customize your server how you like. |
| 104 | + |
| 105 | +# Extras Explained |
| 106 | + |
| 107 | +Here I have 2 raid arrays. |
| 108 | + |
| 109 | +0. Is the NVMe array in RAID1. I have to specify `secondary_pcie_slot0` / `secondary_pcie_slot1` to let the API know what drives to attach to this card. `diskControllerIndex` is 1, because I want it to use the second raid card on my order, `DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2` in this case. |
| 110 | +1. This is for my other drives I'm adding, again in a RAID1. `diskControllerIndex` is 0, because I want it to use the first raid card on my order, `DISK_CONTROLLER_RAID` in this case. |
| 111 | +2. [Advanced Bare Metal Ordering](https://sldn.softlayer.com/python/orderBareMetal/) has some more example of how to setup raid arrays. |
| 112 | + |
| 113 | + |
| 114 | +```json |
| 115 | +{ |
| 116 | + "hardware": [ |
| 117 | + { |
| 118 | + "hostname": "test1nvme", |
| 119 | + "domain": "ibm.com" |
| 120 | + } |
| 121 | + ], |
| 122 | + "storageGroups": [ |
| 123 | + { |
| 124 | + "arraySize": 480, |
| 125 | + "arrayTypeId": 2, |
| 126 | + "diskControllerIndex": 1, |
| 127 | + "hardDriveCategoryCodes": [ |
| 128 | + "secondary_pcie_slot0", |
| 129 | + "secondary_pcie_slot1" |
| 130 | + ] |
| 131 | + }, |
| 132 | + { |
| 133 | + "arraySize": 1920, |
| 134 | + "arrayTypeId": 2, |
| 135 | + "diskControllerIndex": 0, |
| 136 | + "hardDrives": [0,1] |
| 137 | + } |
| 138 | + ] |
| 139 | +} |
| 140 | +``` |
| 141 | + |
| 142 | + |
| 143 | +# Common Errors |
| 144 | + |
| 145 | +## Only 1 RAID card |
| 146 | + |
| 147 | +This order works, but since it only specifies 1 raid card, the other drives will not get attached properly, and will lilely require Datacenter manual intervention to fix this order. Or the drives will be in a JBOD array. |
| 148 | + |
| 149 | + |
| 150 | +```bash |
| 151 | +slcli -v order place --verify 2U_DUAL_INTEL_XEON_SAPPHIRE_RAPIDS_FAMILY_16_DRIVES DALLAS13 \ |
| 152 | +--complex-type SoftLayer_Container_Product_Order_Hardware_Server --billing monthly \ |
| 153 | +--extras '{"hardware":[{"hostname":"test1nvme","domain":"ibm.com"}],"storageGroups":[{"arraySize":480,"arrayTypeId":2,"diskControllerIndex":0,"hardDriveCategoryCodes":["secondary_pcie_slot0","secondary_pcie_slot1"]},{"arraySize":1920,"arrayTypeId":2, "hardDrives":[0,1]}]}' \ |
| 154 | +AUTOMATED_NOTIFICATION MONITORING_HOST_PING NOTIFICATION_EMAIL_AND_TICKET REBOOT_KVM_OVER_IP \ |
| 155 | +UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT BANDWIDTH_0_GB 1_IP_ADDRESS \ |
| 156 | +1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 \ |
| 157 | +MIRRORED_NVME_M_2_OS_BOOT_480GB 256_GB_RAM_DDR5 OS_CENTOS_STREAM_9_X_64_BIT \ |
| 158 | +INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70 REDUNDANT_POWER_SUPPLY HARD_DRIVE_1_9_TB_SSD \ |
| 159 | +HARD_DRIVE_1_9_TB_SSD |
| 160 | +``` |
| 161 | +``` |
| 162 | +┌─────────────────────────────────────────────────────┬────────────────────────────────────────────────┬──────┐ |
| 163 | +│ keyName │ description │ cost │ |
| 164 | +├─────────────────────────────────────────────────────┼────────────────────────────────────────────────┼──────┤ |
| 165 | +│ AUTOMATED_NOTIFICATION │ Automated Notification │ 0 │ |
| 166 | +│ MONITORING_HOST_PING │ Host Ping │ 0 │ |
| 167 | +│ NOTIFICATION_EMAIL_AND_TICKET │ Email and Ticket │ 0 │ |
| 168 | +│ REBOOT_KVM_OVER_IP │ Reboot / KVM over IP │ 0 │ |
| 169 | +│ UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT │ Unlimited SSL VPN Users │ 0 │ |
| 170 | +│ BANDWIDTH_0_GB │ 0 GB Bandwidth Allotment │ 0 │ |
| 171 | +│ 1_IP_ADDRESS │ 1 IP Address │ 0 │ |
| 172 | +│ 1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS │ 1 Gbps Redundant Private Network Uplinks │ 0 │ |
| 173 | +│ DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 │ RAID 1 (Mirrored NVMe M.2) │ 0 │ |
| 174 | +│ MIRRORED_NVME_M_2_OS_BOOT_480GB │ Mirrored NVMe M.2 for OS Boot (480GB) │ 0 │ |
| 175 | +│ 256_GB_RAM_DDR5 │ 256 GB RAM │ 0 │ |
| 176 | +│ OS_CENTOS_STREAM_9_X_64_BIT │ CentOS Stream 9.x (64 bit) │ 0 │ |
| 177 | +│ INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70 │ Dual Intel Xeon Gold 6416H (24 Cores, 2.7 GHz) │ 0 │ |
| 178 | +│ REDUNDANT_POWER_SUPPLY │ Redundant Power Supply │ 0 │ |
| 179 | +│ HARD_DRIVE_1_9_TB_SSD │ 1.9TB SSD │ 0 │ |
| 180 | +│ HARD_DRIVE_1_9_TB_SSD │ 1.9TB SSD │ 0 │ |
| 181 | +└─────────────────────────────────────────────────────┴────────────────────────────────────────────────┴──────┘ |
| 182 | +``` |
| 183 | +## Disk controller #1 is used by storage groups but it does not have a price. |
| 184 | + |
| 185 | +`DISK_CONTROLLER_RAID` is missing from the order |
| 186 | + |
| 187 | +```bash |
| 188 | +slcli -v order place --verify 2U_DUAL_INTEL_XEON_SAPPHIRE_RAPIDS_FAMILY_16_DRIVES DALLAS13 \ |
| 189 | +--complex-type SoftLayer_Container_Product_Order_Hardware_Server --billing monthly \ |
| 190 | +--extras '{"hardware":[{"hostname":"test1nvme","domain":"ibm.com"}],"storageGroups":[{"arraySize":1920,"arrayTypeId":2,"diskControllerIndex": 0,"hardDrives":[0,1]},{"arraySize":480,"arrayTypeId":2,"diskControllerIndex":1,"hardDriveCategoryCodes":["secondary_pcie_slot0","secondary_pcie_slot1"]}]}' \ |
| 191 | +AUTOMATED_NOTIFICATION MONITORING_HOST_PING NOTIFICATION_EMAIL_AND_TICKET REBOOT_KVM_OVER_IP \ |
| 192 | +UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT BANDWIDTH_0_GB 1_IP_ADDRESS \ |
| 193 | +1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 \ |
| 194 | +MIRRORED_NVME_M_2_OS_BOOT_480GB 256_GB_RAM_DDR5 OS_CENTOS_STREAM_9_X_64_BIT \ |
| 195 | +INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70 REDUNDANT_POWER_SUPPLY HARD_DRIVE_1_9_TB_SSD \ |
| 196 | +HARD_DRIVE_1_9_TB_SSD |
| 197 | +``` |
| 198 | +SoftLayerAPIError(500): Disk controller #1 is used by storage groups but it does not have a price. |
| 199 | + |
| 200 | + |
| 201 | +## Unable to add RAID because a Disk Controller price has already been added. |
| 202 | + |
| 203 | +This is caused because older versions of the `slcli`/`ibmcloud sl` are not able to lookup the correct price if there are 2 raid cards in an order. |
| 204 | + |
| 205 | +```bash |
| 206 | +./slcli -v order place --verify 2U_DUAL_INTEL_XEON_SAPPHIRE_RAPIDS_FAMILY_16_DRIVES DALLAS13 \ |
| 207 | +--complex-type SoftLayer_Container_Product_Order_Hardware_Server --billing monthly \ |
| 208 | +--extras '{"hardware":[{"hostname":"test1nvme","domain":"ibm.com"}],"storageGroups":[{"arraySize":1920,"arrayTypeId":2,"diskControllerIndex": 0,"hardDrives":[0,1]},{"arraySize":480,"arrayTypeId":2,"diskControllerIndex":1,"hardDriveCategoryCodes":["secondary_pcie_slot0","secondary_pcie_slot1"]}]}' \ |
| 209 | +AUTOMATED_NOTIFICATION MONITORING_HOST_PING NOTIFICATION_EMAIL_AND_TICKET REBOOT_KVM_OVER_IP \ |
| 210 | +UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT BANDWIDTH_0_GB 1_IP_ADDRESS \ |
| 211 | +1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS DISK_CONTROLLER_RAID \ |
| 212 | +DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 \ |
| 213 | +MIRRORED_NVME_M_2_OS_BOOT_480GB 256_GB_RAM_DDR5 OS_CENTOS_STREAM_9_X_64_BIT \ |
| 214 | +INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70 REDUNDANT_POWER_SUPPLY HARD_DRIVE_1_9_TB_SSD \ |
| 215 | +HARD_DRIVE_1_9_TB_SSD |
| 216 | +``` |
| 217 | +SoftLayerAPIError(500): Unable to add RAID because a Disk Controller price has already been added. |
| 218 | + |
| 219 | + |
| 220 | +## SoftLayerAPIError(500): A storage group with M.2 drive(s) must be the primary storage group. |
| 221 | + |
| 222 | +Storage groups are in the wrong order. |
| 223 | +```bash |
| 224 | +slcli -v order place --verify 2U_DUAL_INTEL_XEON_SAPPHIRE_RAPIDS_FAMILY_16_DRIVES DALLAS13 \ |
| 225 | +--complex-type SoftLayer_Container_Product_Order_Hardware_Server --billing monthly \ |
| 226 | +--extras '{"hardware":[{"hostname":"test1nvme","domain":"ibm.com"}],"storageGroups":[{"arraySize":1920,"arrayTypeId":2,"diskControllerIndex": 0,"hardDrives":[0,1]},{"arraySize":480,"arrayTypeId":2,"diskControllerIndex":1,"hardDriveCategoryCodes":["secondary_pcie_slot0","secondary_pcie_slot1"]}]}' \ |
| 227 | +AUTOMATED_NOTIFICATION MONITORING_HOST_PING NOTIFICATION_EMAIL_AND_TICKET REBOOT_KVM_OVER_IP \ |
| 228 | +UNLIMITED_SSL_VPN_USERS_1_PPTP_VPN_USER_PER_ACCOUNT BANDWIDTH_0_GB 1_IP_ADDRESS \ |
| 229 | +1_GBPS_REDUNDANT_PRIVATE_NETWORK_UPLINKS DISK_CONTROLLER_RAID \ |
| 230 | +DISK_CONTROLLER_RAID_1_MIRRORED_NMVE_M_2 \ |
| 231 | +MIRRORED_NVME_M_2_OS_BOOT_480GB 256_GB_RAM_DDR5 OS_CENTOS_STREAM_9_X_64_BIT \ |
| 232 | +INTEL_INTEL_XEON_6416_UEFI_BOOT_MODE_2_70 REDUNDANT_POWER_SUPPLY HARD_DRIVE_1_9_TB_SSD \ |
| 233 | +HARD_DRIVE_1_9_TB_SSD |
| 234 | +``` |
| 235 | +SoftLayerAPIError(500): A storage group with M.2 drive(s) must be the primary storage group. |