Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathSPM02_Z3_Local_02.js
230 lines (211 loc) · 13.7 KB
/
SPM02_Z3_Local_02.js
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
/**********************************************************************
Version 01.00.02
Date 2023/10/26
update 支持读取总有功功率,三相无功功率,总无功功率,
三相势在功率,总势在功率,系统频率
**********************************************************************/
const fz = require('zigbee-herdsman-converters/converters/fromZigbee');
const tz = require('zigbee-herdsman-converters/converters/toZigbee');
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const extend = require('zigbee-herdsman-converters/lib/extend');
const e = exposes.presets;
const ea = exposes.access;
const { Numeric } = require('zigbee-herdsman-converters/lib/exposes');
const {
precisionRound, mapNumberRange, isLegacyEnabled, toLocalISOString, numberWithinRange, hasAlreadyProcessedMessage,
calibrateAndPrecisionRoundOptions, addActionGroup, postfixWithEndpointName, getKey,
batteryVoltageToPercentage,
} = require('zigbee-herdsman-converters/lib/utils');
const utils = require('zigbee-herdsman-converters/lib/utils');
let preEnergy = 0;
let preProduced_energy = 0;
const converters = {
seMetering: {
cluster: 'seMetering',
type: ['attributeReport', 'readResponse'],
options: (definition) => {
const result = [];
if (definition.exposes.find((e) => e.name === 'power')) {
result.push(exposes.options.precision('power'), exposes.options.calibration('power', 'percentual'));
}
if (definition.exposes.find((e) => e.name === 'energy')) {
result.push(exposes.options.precision('energy'), exposes.options.calibration('energy', 'percentual'));
}
if (definition.exposes.find((e) => e.name === 'produced_energy')) {
result.push(exposes.options.precision('produced_energy'), exposes.options.calibration('energy', 'percentual'));
}
return result;
},
convert: (model, msg, publish, options, meta) => {
if (utils.hasAlreadyProcessedMessage(msg, model)) return;
const payload = {};
const multiplier = msg.endpoint.getClusterAttributeValue('seMetering', 'multiplier');
const divisor = msg.endpoint.getClusterAttributeValue('seMetering', 'divisor');
const factor = multiplier && divisor ? multiplier / divisor : null;
if (factor != null && (msg.data.hasOwnProperty('currentSummDelivered') ||
msg.data.hasOwnProperty('currentSummReceived'))) {
let energy = preEnergy;
let produced_energy = preProduced_energy;
if (msg.data.hasOwnProperty('currentSummDelivered')) {
const data = msg.data['currentSummDelivered'];
const value = (parseInt(data[0]) << 32) + parseInt(data[1]);
energy = value * factor;
preEnergy = energy;
// produced_energy = preProduced_energy;
}
if (msg.data.hasOwnProperty('currentSummReceived')) {
const data = msg.data['currentSummReceived'];
const value = (parseInt(data[0]) << 32) + parseInt(data[1]);
produced_energy = value * factor;
preProduced_energy = produced_energy;
// energy = preEnergy;
}
payload.energy = calibrateAndPrecisionRoundOptions(energy, options, 'energy');
payload.produced_energy = calibrateAndPrecisionRoundOptions(produced_energy, options, 'energy');
// payload.produced_energy = produced_energy;
}
return payload;
},
},
electrical_measurement_bituo: {
//bituo-SPM02
cluster: 'haElectricalMeasurement',
type: ['attributeReport', 'readResponse'],
options: [
exposes.options.precision('ac_frequency'), exposes.options.precision('total_active_power'),
exposes.options.calibration('active_power', 'percentual'), exposes.options.precision('active_power'),
exposes.options.precision('active_power_phase_b'), exposes.options.precision('active_power_phase_c'),
exposes.options.precision('total_power_apparent'), exposes.options.precision('power_apparent'),
exposes.options.precision('power_apparent_phase_b'), exposes.options.precision('power_apparent_phase_c'),
exposes.options.precision('total_power_reactive'), exposes.options.precision('power_reactive'),
exposes.options.precision('power_reactive_phase_b'), exposes.options.precision('power_reactive_phase_c'),
exposes.options.calibration('current', 'percentual'), exposes.options.precision('current'),
exposes.options.calibration('voltage', 'percentual'), exposes.options.precision('voltage'),
],
convert: (model, msg, publish, options, meta) => {
if (utils.hasAlreadyProcessedMessage(msg, model)) return;
const getFactor = (key) => {
const multiplier = msg.endpoint.getClusterAttributeValue('haElectricalMeasurement', `${key}Multiplier`);
const divisor = msg.endpoint.getClusterAttributeValue('haElectricalMeasurement', `${key}Divisor`);
const factor = multiplier && divisor ? multiplier / divisor : 1;
return factor;
};
const lookup = [
{key: 'activePower', name: 'active_power', factor: 'acPower'},
{key: 'activePowerPhB', name: 'active_power_phase_b', factor: 'acPower'},
{key: 'activePowerPhC', name: 'active_power_phase_c', factor: 'acPower'},
{key: 'totalActivePower', name: 'total_active_power', factor: 'acPower'},
{key: 'apparentPower', name: 'power_apparent', factor: 'acPower'},
{key: 'apparentPowerPhB', name: 'power_apparent_phase_b', factor: 'acPower'},
{key: 'apparentPowerPhC', name: 'power_apparent_phase_c', factor: 'acPower'},
{key: 'totalAppaarentPower', name: 'total_power_apparent', factor: 'acPower'},
{key: 'reactivePower', name: 'power_reactive', factor: 'acPower'},
{key: 'reactivePowerPhB', name: 'power_reactive_phase_b', factor: 'acPower'},
{key: 'reactivePowerPhC', name: 'power_reactive_phase_c', factor: 'acPower'},
{key: 'totalReactivePower', name: 'total_power_reactive', factor: 'acPower'},
{key: 'rmsCurrent', name: 'current', factor: 'acCurrent'},
{key: 'rmsCurrentPhB', name: 'current_phase_b', factor: 'acCurrent'},
{key: 'rmsCurrentPhC', name: 'current_phase_c', factor: 'acCurrent'},
{key: 'rmsVoltage', name: 'voltage', factor: 'acVoltage'},
{key: 'rmsVoltagePhB', name: 'voltage_phase_b', factor: 'acVoltage'},
{key: 'rmsVoltagePhC', name: 'voltage_phase_c', factor: 'acVoltage'},
{key: 'acFrequency', name: 'ac_frequency', factor: 'acFrequency'},
];
const payload = {};
for (const entry of lookup) {
if (msg.data.hasOwnProperty(entry.key)) {
const factor = getFactor(entry.factor);
const property = postfixWithEndpointName(entry.name, msg, model, meta);
const value = msg.data[entry.key] * factor;
payload[property] = calibrateAndPrecisionRoundOptions(value, options, entry.name);
}
}
// alarm mask
if(msg.data.hasOwnProperty('ACAlarmsMask')){
payload.Alarm = msg.data['ACAlarmsMask'].toString(2);
}
if (msg.data.hasOwnProperty('powerFactor')) {
payload.power_factor = precisionRound(msg.data['powerFactor'] , 2);
}
if (msg.data.hasOwnProperty('powerFactorPhB')) {
payload.power_factor_phase_b = precisionRound(msg.data['powerFactorPhB'] , 2);
}
if (msg.data.hasOwnProperty('powerFactorPhC')) {
payload.power_factor_phase_c = precisionRound(msg.data['powerFactorPhC'] , 2);
}
return payload;
},
},
hw_version: {
cluster: 'genBasic',
type: ['attributeReport', 'readResponse'],
convert: (model, msg, publish, options, meta) => {
const result = {};
if (msg.data.hasOwnProperty('hwVersion')) result['hw_version'] = msg.data.hwVersion;
return result;
},
},
locationDesc: {
cluster: 'genBasic',
type: ['attributeReport', 'readResponse'],
convert: (model, msg, publish, options, meta) => {
const result = {};
if (msg.data.hasOwnProperty('locationDesc')) result['locationDesc'] = msg.data.locationDesc;
return result;
},
},
}
const power_kW = () => new Numeric('active_power', ea.STATE).withUnit('kW').withDescription('Instantaneous measured active power');
const power_kW_phase_b = () => new Numeric('active_power_phase_b', ea.STATE).withUnit('kW').withDescription('Instantaneous measured active power on phase B');
const power_kW_phase_c = () => new Numeric('active_power_phase_c', ea.STATE).withUnit('kW').withDescription('Instantaneous measured active power on phase C');
const total_power_kW = () => new Numeric('total_active_power', ea.STATE).withUnit('kW').withDescription('Instantaneous measured total active power');
const power_factor_phase_b = () => new Numeric('power_factor_phase_b', ea.STATE).withUnit('%').withDescription('Instantaneous measured power factor on phase B');
const power_factor_phase_c = () => new Numeric('power_factor_phase_c', ea.STATE).withUnit('%').withDescription('Instantaneous measured power factor on phase C');
const power_reactive = () => new Numeric('power_reactive', ea.STATE).withUnit('kVAR').withDescription('Instantaneous measured reactive power');
const power_reactive_phase_b = () => new Numeric('power_reactive_phase_b', ea.STATE).withUnit('kVAR').withDescription('Instantaneous measured reactive power on phase B');
const power_reactive_phase_c = () => new Numeric('power_reactive_phase_c', ea.STATE).withUnit('kVAR').withDescription('Instantaneous measured reactive power on phase C');
const total_power_reactive = () => new Numeric('total_power_reactive', ea.STATE).withUnit('kVAR').withDescription('Instantaneous measured total reactive power');
const power_apparent = () => new Numeric('power_apparent', ea.STATE).withUnit('kVA').withDescription('Instantaneous measured apparent power');
const power_apparent_phase_b = () => new Numeric('power_apparent_phase_b', ea.STATE).withUnit('kVA').withDescription('Instantaneous measured apparent power on phase B');
const power_apparent_phase_c = () => new Numeric('power_apparent_phase_c', ea.STATE).withUnit('kVA').withDescription('Instantaneous measured apparent power on phase C');
const total_power_apparent = () => new Numeric('total_power_apparent', ea.STATE).withUnit('kVA').withDescription('Instantaneous measured total apparent power');
const hw_version = () => new Numeric('hw_version', ea.STATE).withUnit(' ').withDescription('Hardware Version');
const locationDesc = () => new Numeric('locationDesc', ea.STATE).withUnit(' ').withDescription('Zigbee Version');
const definition = {
zigbeeModel: ['SPM02X001'],// The model ID from: Device with modelID 'lumi.sens' is not supported.
model: 'SPM02X001', // Vendor model number, look on the device for a model number
vendor: 'BITUO TECHNIK', // Vendor of the device (only used for documentation and startup logging)
description: 'Smart energy monitor for 3P+N system',
fromZigbee: [converters.electrical_measurement_bituo, converters.seMetering, converters.hw_version, converters.locationDesc],
toZigbee: [],
//configure: tuya.configureMagicPacket,
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);// 选取1为服务端点,spm0x只有1
await reporting.bind(endpoint, coordinatorEndpoint, ['haElectricalMeasurement', 'seMetering', 'genBasic']);// 将端点1与haElectricalMeasurement绑定
await reporting.readEletricalMeasurementMultiplierDivisors(endpoint);// 读取电力测量的乘法因子和除法因子
await reporting.readMeteringMultiplierDivisor(endpoint);
await reporting.activePower(endpoint);// 有功功率
await reporting.rmsCurrent(endpoint);// 电流
await reporting.rmsVoltage(endpoint);// 电压
await reporting.powerFactor(endpoint);
await reporting.apparentPower(endpoint);
await reporting.reactivePower(endpoint);
await reporting.currentSummDelivered(endpoint);
await reporting.currentSummReceived(endpoint);
device.save();
},
exposes: [e.ac_frequency(), e.voltage(), e.voltage_phase_b(), e.voltage_phase_c(),
power_kW(), power_kW_phase_b(), power_kW_phase_c(), total_power_kW(),
e.current(), e.current_phase_b(), e.current_phase_c(),
e.power_factor(), power_factor_phase_b(), power_factor_phase_c(),
power_reactive(), power_reactive_phase_b(), power_reactive_phase_c(), total_power_reactive(),
power_apparent(), power_apparent_phase_b(), power_apparent_phase_c(), total_power_apparent(),
// Change the description according to the specifications of the device
e.energy().withDescription('Total forward active energy'),
e.produced_energy().withDescription('Total reverse active energy'),
hw_version(), locationDesc(),
//e.paySwitch().withDescription('预付费开关'),
],
};
module.exports = definition;