2025-01-31 11:11:12.764 WARNING (MainThread) [custom_components.tuya_local.config_flow] Device matches stepuptech_solar_inverter_v2 with quality of 24%. DPS: {"updated_at": 1738318270.3997474, "1": true, "2": "heating", "4": 25, "103": 20, "104": 0, "105": 12, "106": -4, "107": 15, "108": 40, "109": 7, "110": "COOL", "111": 0, "112": 0, "113": 226, "114": -420, "115": 225, "116": 300, "117": 54, "118": 45, "119": 220, "120": 142, "121": 400, "122": 0, "123": 0, "124": 0, "125": 3, "127": 0, "129": 0, "130": 317, "131": 233, "132": 0, "133": 0, "135": 0, "136": "para_p"} 2025-01-31 11:11:12.764 WARNING (MainThread) [custom_components.tuya_local.config_flow] Include the previous log messages with any new device request to https://github.com/make-all/tuya-local/issues/
tf8ykxqlvmhbh3to
Alsavo heat pump
{ "result": { "properties": [ { "code": "switch", "custom_name": "On/Off", "dp_id": 1, "time": 1738266238578, "type": "bool", "value": true }, { "code": "mode", "custom_name": "Heat pump mode", "dp_id": 2, "time": 1738256089445, "type": "enum", "value": "heating" }, { "code": "temp_set", "custom_name": "Temprature setpoint", "dp_id": 4, "time": 1738303582795, "type": "value", "value": 26 }, { "code": "SET_TANK_TEMP", "custom_name": "DHW water tank setpoint", "dp_id": 103, "time": 1738252316140, "type": "value", "value": 20 }, { "code": "fault_num", "custom_name": "", "dp_id": 104, "time": 1738256089481, "type": "value", "value": 0 }, { "code": "SET_COOL_TEMP", "custom_name": "Cooling setpoint", "dp_id": 105, "time": 1738303215593, "type": "value", "value": 12 }, { "code": "SET_DEFIN_TEMP", "custom_name": "Start defrost temp", "dp_id": 106, "time": 1738252395377, "type": "value", "value": -4 }, { "code": "SET_DEFOUT_TEMP", "custom_name": "stop defrost temp", "dp_id": 107, "time": 1738252316209, "type": "value", "value": 15 }, { "code": "SET_DEF_LOOPTIME", "custom_name": "Defrost cycle", "dp_id": 108, "time": 1738252316227, "type": "value", "value": 40 }, { "code": "SET_DEF_MAXTIME", "custom_name": "Max defrost time", "dp_id": 109, "time": 1738256061484, "type": "value", "value": 7 }, { "code": "RUN_MODE", "custom_name": "Cool or Heat", "dp_id": 110, "time": 1738256167674, "type": "enum", "value": "COOL" }, { "code": "RUN_FREQUENT", "custom_name": "Frequent of heat pump in hz", "dp_id": 111, "time": 1738316392404, "type": "value", "value": 43 }, { "code": "RUN_CURRENT", "custom_name": "used current in A", "dp_id": 112, "time": 1738316396419, "type": "value", "value": 0 }, { "code": "WATER_BACK_TEMP", "custom_name": "Return temp", "dp_id": 113, "time": 1738317853504, "type": "value", "value": 233 }, { "code": "WATER_TANK_TEMP", "custom_name": "Water tank temp", "dp_id": 114, "time": 1738252316340, "type": "value", "value": -420 }, { "code": "WATER_OUT_TEMP", "custom_name": "Water outlet temp", "dp_id": 115, "time": 1738317629181, "type": "value", "value": 236 }, { "code": "SYS_PQ_TEMP", "custom_name": "", "dp_id": 116, "time": 1738317542161, "type": "value", "value": 330 }, { "code": "OUT_TEMP", "custom_name": "Outside temprature", "dp_id": 117, "time": 1738317856565, "type": "value", "value": 49 }, { "code": "SYS_PG_TEMP", "custom_name": "", "dp_id": 118, "time": 1738317872576, "type": "value", "value": 41 }, { "code": "SYS_BACK_TEMP", "custom_name": "", "dp_id": 119, "time": 1738317860603, "type": "value", "value": 205 }, { "code": "SYS_JIEL_TEMP", "custom_name": "", "dp_id": 120, "time": 1738317782498, "type": "value", "value": 145 }, { "code": "MIAN_EVI_STEP", "custom_name": "", "dp_id": 121, "time": 1738315218667, "type": "value", "value": 400 }, { "code": "PROTECT_FLAG", "custom_name": "", "dp_id": 122, "time": 1738252316503, "type": "value", "value": 0 }, { "code": "TRAGE_FREQUENT", "custom_name": "Target frequint of heat pump", "dp_id": 123, "time": 1738315217663, "type": "value", "value": 0 }, { "code": "EVI_STEP", "custom_name": "", "dp_id": 124, "time": 1738314706925, "type": "value", "value": 60 }, { "code": "IPM_TEMP", "custom_name": "", "dp_id": 125, "time": 1738317847618, "type": "value", "value": 3 }, { "code": "pro_flag1", "custom_name": "", "dp_id": 127, "time": 1738256089850, "type": "value", "value": 0 }, { "code": "pro_flag2", "custom_name": "", "dp_id": 129, "time": 1738252316603, "type": "value", "value": 0 }, { "code": "DCBUS_VOL", "custom_name": "", "dp_id": 130, "time": 1738317832679, "type": "value", "value": 317 }, { "code": "ACIN_VOL", "custom_name": "", "dp_id": 131, "time": 1738317760551, "type": "value", "value": 232 }, { "code": "pro_flag3", "custom_name": "", "dp_id": 132, "time": 1738252316666, "type": "value", "value": 0 }, { "code": "pro_flag4", "custom_name": "", "dp_id": 133, "time": 1738252316686, "type": "value", "value": 0 }, { "code": "datebuf_address", "custom_name": "", "dp_id": 134, "time": 1738162627106, "type": "value", "value": 0 }, { "code": "datebuf_value", "custom_name": "", "dp_id": 135, "time": 1738252316705, "type": "value", "value": 0 }, { "code": "para_type", "custom_name": "", "dp_id": 136, "time": 1738252316723, "type": "enum", "value": "para_p" } ] }, "success": true, "t": 1738317876631, "tid": "c6e96aaadfba11ef9e609e9247cde4aa" }
I tried to add the custom names as explanation. for help or quistions i'm always avadible.
The text was updated successfully, but these errors were encountered:
No branches or pull requests
Log message
Product ID
tf8ykxqlvmhbh3to
Product Name
Alsavo heat pump
DPS information
Information about how the device functions
I tried to add the custom names as explanation. for help or quistions i'm always avadible.