All profiles (should) correspond to the official EEP by EnOcean.
F6 (RPS Telegram)
01 (Switch Buttons)
F6-01-01 (Push Button)
shortcut description type values PB Status of the push button enum 0 - Released 1 - Pressed 02 (Rocker Switch, 2 Rocker)
F6-02-01 (Light and Blind Control - Application Style 1)
shortcut description type values R1 Rocker 1st action enum 0 - Button AI 1 - Button AO 2 - Button BI 3 - Button BO EB Energy bow enum 0 - released 1 - pressed R2 Rocker 2nd action enum 0 - Button AI 1 - Button AO 2 - Button BI 3 - Button BO SA 2nd action enum 0 - No 2nd action 1 - 2nd action valid T21 T21 status NU NU status F6-02-02 (Light and Blind Control - Application Style 2)
shortcut description type values R1 Rocker 1st action enum 0 - Button AI 1 - Button AO 2 - Button BI 3 - Button BO EB Energy bow enum 0 - released 1 - pressed R2 Rocker 2nd action enum 0 - Button AI 1 - Button AO 2 - Button BI 3 - Button BO SA 2nd action enum 0 - No 2nd action 1 - 2nd action valid T21 T21 status NU NU status 04 (Position Switch, Home and Office Application)
F6-04-01 (Key Card Activated Switch)
shortcut description type values KC Key Card enum 0 - Taken out 112 - Inserted T21 T21 status NU NU status 05 (Detectors)
F6-05-01 (Liquid Leakage Sensor (mechanic harvester))
shortcut description type values WAS Water Sensor enum 0-16 - not specified 17 - Water detected 18-255 - not specified T21 T21 status NU NU status F6-05-02 (Smoke Detector)
shortcut description type values SMO Status of detection and battery enum 0 - Smoke Alarm OFF 16 - Smoke Alarm ON 48 - Energy LOW 10 (Mechanical Handle)
F6-10-00 (Window Handle)
shortcut description type values WIN Window handle enum 0 - Moved from up to vertical 1 - Moved from vertical to up 2 - Moved from down to vertical 3 - Moved from vertical to down T21 T21 status NU NU status
D5 (1BS Telegram)
00 (Contacts and Switches)
D5-00-01 (Single Input Contact)
shortcut description type values CO Contact enum 0 - open 1 - closed
A5 (4BS Telegram)
02 (Temperature Sensors)
A5-02-01 (Temperature Sensor Range -40°C to 0°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -40.0-0.0 °C A5-02-02 (Temperature Sensor Range -30°C to +10°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -30.0-10.0 °C A5-02-03 (Temperature Sensor Range -20°C to +20°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -20.0-20.0 °C A5-02-04 (Temperature Sensor Range -10°C to +30°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -10.0-30.0 °C A5-02-05 (Temperature Sensor Range 0°C to +40°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C A5-02-06 (Temperature Sensor Range +10°C to +50°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 10.0-50.0 °C A5-02-07 (Temperature Sensor Range +20°C to +60°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 20.0-60.0 °C A5-02-08 (Temperature Sensor Range +30°C to +70°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 30.0-70.0 °C A5-02-09 (Temperature Sensor Range +40°C to +80°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 40.0-80.0 °C A5-02-0A (Temperature Sensor Range +50°C to +90°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 50.0-90.0 °C A5-02-0B (Temperature Sensor Range +60°C to +100°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 60.0-100.0 °C A5-02-10 (Temperature Sensor Range -60°C to +20°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -60.0-20.0 °C A5-02-11 (Temperature Sensor Range -50°C to +30°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -50.0-30.0 °C A5-02-12 (Temperature Sensor Range -40°C to +40°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -40.0-40.0 °C A5-02-13 (Temperature Sensor Range -30°C to +50°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -30.0-50.0 °C A5-02-14 (Temperature Sensor Range -20°C to +60°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -20.0-60.0 °C A5-02-15 (Temperature Sensor Range -10°C to +70°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ -10.0-70.0 °C A5-02-16 (Temperature Sensor Range 0°C to +80°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-80.0 °C A5-02-17 (Temperature Sensor Range +10°C to +90°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 10.0-90.0 °C A5-02-18 (Temperature Sensor Range +20°C to +100°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 20.0-100.0 °C A5-02-19 (Temperature Sensor Range +30°C to +110°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 30.0-110.0 °C A5-02-1A (Temperature Sensor Range +40°C to +120°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 40.0-120.0 °C A5-02-1B (Temperature Sensor Range +50°C to +130°C)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 50.0-130.0 °C A5-02-20 (10 Bit Temperature Sensor Range -10°C to +41.2°C)
shortcut description type values TMP Temperature (linear) value 1023.0-0.0 ↔ -10.0-41.2 °C A5-02-30 (10 Bit Temperature Sensor Range -40°C to +62.3°C)
shortcut description type values TMP Temperature (linear) value 1023.0-0.0 ↔ -40.0-62.3 °C 04 (Temperature and Humidity Sensor)
A5-04-01 (Range 0°C to +40°C and 0% to 100%)
shortcut description type values HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 % TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C TSN Availability of the Temperature Sensor enum 0 - not available 1 - available A5-04-02 (Range -20°C to +60°C and 0% to 100%)
shortcut description type values HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 % TMP Temperature (linear) value 0.0-250.0 ↔ -20.0-60.0 °C TSN Availability of the Temperature Sensor enum 0 - not available 1 - available A5-04-03 (Range -20°C to +60°C 10bit-measurement and 0% to 100%)
shortcut description type values HUM Rel. Humidity (linear) value 0.0-255.0 ↔ 0.0-100.0 % TMP Temperature (linear) value 0.0-1023.0 ↔ -20.0-60.0 °C TTP Telegram Type enum 0 - Heartbeat 1 - Event triggered A5-04-04 (Range -40°C to +120°C 12bit-measurement and 0% to 100%)
shortcut description type values HUM Rel. Humidity (linear) value 0.0-199.0 ↔ 0.0-100.0 % TMP Temperature (linear) value 0.0-1599.0 ↔ -40.0-120.0 °C 06 (Light Sensor)
A5-06-01 (Range 300lx to 60.000lx)
shortcut description type values SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V ILL2 Illumination 2 (linear) value 0.0-255.0 ↔ 300.0-30000.0 lx ILL1 Illumination 1 (linear) value 0.0-255.0 ↔ 600.0-60000.0 lx RS Range select enum 0 - Range acc. to DB_1 (ILL1) 1 - Range acc. to DB_2 (ILL2) A5-06-02 (Range 0lx to 1.020lx)
shortcut description type values SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V ILL2 Illumination 2 (linear) value 0.0-255.0 ↔ 0.0-510.0 lx ILL1 Illumination 1 (linear) value 0.0-255.0 ↔ 0.0-1020.0 lx RS Range select enum 0 - Range acc. to DB_1 (ILL1) 1 - Range acc. to DB_2 (ILL2) 07 (Occupancy Sensor)
A5-07-01 (Occupancy with Supply voltage monitor)
shortcut description type values SVC Supply voltage (OPTIONAL) value 0.0-250.0 ↔ 0.0-5.0 V PIRS PIR Status enum 0 - PIR off 1 - PIR on SVA Supply voltage availability enum 0 - Supply voltage is not supported 1 - Supply voltage is supported A5-07-02 (Occupancy with Supply voltage monitor)
shortcut description type values SVC Supply voltage (REQUIRED) value 0.0-250.0 ↔ 0.0-5.0 V PIRS PIR Status enum 0 - Uncertain of occupancy status 1 - Motion detected A5-07-03 (Occupancy with Supply voltage monitor)
shortcut description type values SVC Supply voltage (REQUIRED) value 0.0-250.0 ↔ 0.0-5.0 V ILL Illumination value 0.0-1000.0 ↔ 0.0-1000.0 lx PIRS PIR Status enum 0 - Uncertain of occupancy status 1 - Motion detected 08 (Light, Temperature and Occupancy Sensor)
A5-08-01 (Range 0lx to 510lx, 0°C to +51°C and Occupancy Button)
shortcut description type values SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V ILL Illumination (linear) value 0.0-255.0 ↔ 0.0-510.0 lx TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C PIRS PIR Status enum 0 - PIR on 1 - PIR off OCC Occupancy Button enum 0 - Button pressed 1 - Button released A5-08-02 (Range 0lx to 1020lx, 0°C to +51°C and Occupancy Button)
shortcut description type values SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V ILL Illumination (linear) value 0.0-255.0 ↔ 0.0-1020.0 lx TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C PIRS PIR Status enum 0 - PIR on 1 - PIR off OCC Occupancy Button enum 0 - Button pressed 1 - Button released A5-08-03 (Range 0lx to 1530lx, -30°C to +51°C and Occupancy Button)
shortcut description type values SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V ILL Illumination (linear) value 0.0-255.0 ↔ 0.0-1530.0 lx TMP Temperature (linear) value 0.0-255.0 ↔ -30.0-50.0 °C PIRS PIR Status enum 0 - PIR on 1 - PIR off OCC Occupancy Button enum 0 - Button pressed 1 - Button released 09 (Gas Sensor)
A5-09-04 (CO2 Sensor)
shortcut description type values HUM Rel. Humidity (linear) value 0.0-200.0 ↔ 0.0-100.0 % Conc Concentration (linear) value 0.0-255.0 ↔ 0.0-2550.0 ppm TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C HSN Availability of the Humidity Sensor enum 0 - not available 1 - available TSN Availability of the Temperature Sensor enum 0 - not available 1 - available A5-09-05 (VOC Sensor)
shortcut description type values Conc VOC Concentration value 0.0-65535.0 ↔ 0.0-65535.0 ppb VOC_ID VOC Identification enum 0 - VOCT (total) 1 - Formaldehyde 2 - Benzene 3 - Styrene 4 - Toluene 5 - Tetrachloroethylene 6 - Xylene 7 - n-Hexane 8 - n-Octane 9 - Cyclopentane 10 - Methanol 11 - Ethanol 12 - 1-Pentanol 13 - Acetone 14 - ethylene Oxide 15 - Acetaldehyde ue 16 - Acetic Acid 17 - Propionice Acid 18 - ValericAcid 19 - ButyricAcid 20 - Ammoniac 22 - Hydrogen Sulfide 23 - Dimethylsulfide 24 - 2-Butanol (butyl Alcohol) 25 - 2-Methylpropanol 26 - Diethyl ether 255 - ozone 10 (Room Operating Panel)
A5-10-03 (Temperature Sensor and Set Point)
shortcut description type values SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C A5-10-05 (Temperature Sensor, Set Point and Occupancy Control)
shortcut description type values SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C OCC Occupancy Button enum 0 - Button pressed 1 - Button released A5-10-06 (Temperature Sensor, Set Point and Day/Night Control)
shortcut description type values SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C SLSW Slide switch enum 0 - Position I / Night / Off 1 - Position O / Day / On A5-10-10 (Temperature and Humidity Sensor, Set Point and Occupancy Control)
shortcut description type values SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 % TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C OCC Occupancy Button enum 0 - Button pressed 1 - Button released A5-10-12 (Temperature and Humidity Sensor and Set Point)
shortcut description type values SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 % TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C 11 (Controller Status)
A5-11-02 (Temperature Controller Output)
shortcut description type values CVAR Actual value of controller value 0.0-255.0 ↔ 0.0-100.0 % FAN Actual value of fan enum 0 - State 0 Manual 1 - State 1 Manual 2 - State 2 Manual 3 - State 3 Manual 16 - State 0 Automatic 17 - State 1 Automatic 18 - State 2 Automatic 19 - State 3 Automatic 255 - Not Available ASP Actual Setpoint value 0.0-255.0 ↔ 0.0-51.2 C ALR Alarm enum 0 - No alarm 1 - Alarm CTM Controller mode enum 1 - Heating 2 - Cooling 3 - Off CTS Controller state enum 0 - Automatic 1 - Override ERH Energy hold-off enum 0 - Normal 1 - Energy hold-off / Dew point RO Room occupancy enum 0 - Occupied 1 - Unoccupied 2 - StandBy 3 - Frost A5-11-03 (Blind Status)
shortcut description type values BSP Blind/shutter position value 0.0-100.0 ↔ 0.0-100.0 % AS Angle sign enum 0 - Positive sign 1 - Negative sign AN Angle in 2 degrees steps value 0.0-90.0 ↔ 0.0-180.0 degrees PVF Position value flag enum 0 - No position value available 1 - Position value available AVF Angle value flag enum 0 - No Angle value available 1 - Angle value available ES Error state enum 0 - No error present 1 - End-positions are not configured 2 - Internal failure 3 - Not used EP End position enum 0 - No End-position available 1 - No End-position reached 2 - Blind fully open 3 - Blind fully closed ST Status enum 0 - No status available 1 - Blind is stopped 2 - Blind opens 3 - Blind closes SM Service mode enum 0 - Normal mode 1 - Service mode activated MOTP Mode of the position enum 0 - Normal mode 1 - Inverse ode 12 (Automated Meter Reading (AMR))
A5-12-00 (Counter)
shortcut description type values MR Current value in or cumulative counter value value 0.0-16777215.0 ↔ 0.0-16777215.0 CH Measurement channel value 0.0-15.0 ↔ 0.0-15.0 DT Current value or cumulative counter value enum 0 - Cumulative value 1 - Current value DIV Divisor for value enum 0 - x/1 1 - x/10 2 - x/100 3 - x/1000 A5-12-01 (Electricity)
shortcut description type values MR current value in W or cumulative value in kWh value 0.0-16777215.0 ↔ 0.0-16777215.0 TI Tariff info value 0.0-15.0 ↔ 0.0-15.0 DT Current value or cumulative value enum 0 - kWh 1 - W DIV Divisor for value enum 0 - x/1 1 - x/10 2 - x/100 3 - x/1000 13 (Environmental Applications)
A5-13-01 (Weather Station)
shortcut description type values DWS Dawn sensor value 0.0-255.0 ↔ 0.0-999.0 lx TMP Outdoor Temp value 0.0-255.0 ↔ -40.0-80.0 °C WND Wind speed value 0.0-255.0 ↔ 0.0-70.0 m/s ID Identifier enum 0-15 - Identifier {value} DN Day / Night enum 0 - Day 1 - Night RAN Rain Indication enum 0 - No Rain 1 - Rain
shortcut description type values SNW Sun - West value 0.0-255.0 ↔ 0.0-150.0 klx SNS Sun - South value 0.0-255.0 ↔ 0.0-150.0 klx SNE Sun - East value 0.0-255.0 ↔ 0.0-150.0 klx ID Identifier enum 0-15 - Identifier {value} HEM Hemisphere enum 0 - North 1 - South
shortcut description type values DY Day value 1.0-31.0 ↔ 1.0-31.0 MTH Month value 1.0-12.0 ↔ 1.0-12.0 YR Year value 0.0-99.0 ↔ 2000.0-2099.0 ID Identifier enum 0-15 - Identifier {value} SRC Source enum 0 - Real Time Clock 1 - GPS or equivalent (e.g. DCF77, WWV)
shortcut description type values WDY Weekday enum 1 - Monday 2 - Tuesday 3 - Wednesday 4 - Thursday 5 - Friday 6 - Saturday 7 - Sunday HR Hour value 0.0-23.0 ↔ 0.0-23.0 MIN Minute value 0.0-59.0 ↔ 0.0-59.0 SEC Second value 0.0-59.0 ↔ 0.0-59.0 ID Identifier enum 0-15 - Identifier {value} TMF Time Format enum 0 - 24 Hours 1 - 12 Hours AMPM AM/PM enum 0 - AM 1 - PM SRC Source enum 0 - Real Time Clock 1 - GPS or equivalent (e.g. DCF77, WWV)
shortcut description type values ELV Elevation value 0.0-180.0 ↔ -90.0-90.0 ° AZM Azimut value 0.0-359.0 ↔ 0.0-359.0 ° ID Identifier enum 0-15 - Identifier {value}
shortcut description type values LAT_MSB Latitude(MSB) value 0.0-15.0 ↔ 0.0-15.0 LOT_MSB Longitude(MSB) value 0.0-15.0 ↔ 0.0-15.0 LAT_LSB Latitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 ° LOT_LSB Longitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 ° ID Identifier enum 0-15 - Identifier {value} A5-13-02 (Sun Intensity)
shortcut description type values SNW Sun - West value 0.0-255.0 ↔ 0.0-150.0 klx SNS Sun - South value 0.0-255.0 ↔ 0.0-150.0 klx SNE Sun - East value 0.0-255.0 ↔ 0.0-150.0 klx ID Identifier enum 0-15 - Identifier {value} HEM Hemisphere enum 0 - North 1 - South A5-13-03 (Date Exchange)
shortcut description type values DY Day value 1.0-31.0 ↔ 1.0-31.0 MTH Month value 1.0-12.0 ↔ 1.0-12.0 YR Year value 0.0-99.0 ↔ 2000.0-2099.0 ID Identifier enum 0-15 - Identifier {value} SRC Source enum 0 - Real Time Clock 1 - GPS or equivalent (e.g. DCF77, WWV) A5-13-04 (Time and Day Exchange)
shortcut description type values WDY Weekday enum 1 - Monday 2 - Tuesday 3 - Wednesday 4 - Thursday 5 - Friday 6 - Saturday 7 - Sunday HR Hour value 0.0-23.0 ↔ 0.0-23.0 MIN Minute value 0.0-59.0 ↔ 0.0-59.0 SEC Second value 0.0-59.0 ↔ 0.0-59.0 ID Identifier enum 0-15 - Identifier {value} TMF Time Format enum 0 - 24 Hours 1 - 12 Hours AMPM AM/PM enum 0 - AM 1 - PM SRC Source enum 0 - Real Time Clock 1 - GPS or equivalent (e.g. DCF77, WWV) A5-13-05 (Direction Exchange)
shortcut description type values ELV Elevation value 0.0-180.0 ↔ -90.0-90.0 ° AZM Azimut value 0.0-359.0 ↔ 0.0-359.0 ° ID Identifier enum 0-15 - Identifier {value} A5-13-06 (Geographic Position Exchange)
shortcut description type values LAT_MSB Latitude(MSB) value 0.0-15.0 ↔ 0.0-15.0 LOT_MSB Longitude(MSB) value 0.0-15.0 ↔ 0.0-15.0 LAT_LSB Latitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 ° LOT_LSB Longitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 ° ID Identifier enum 0-15 - Identifier {value} 14 (Multi-Func Sensor)
A5-14-01 (Single Input Contact (Window/Door), Supply voltage monitor)
shortcut description type values SVC Supply voltage / super cap. (linear); 251 - 255 reserved for error code value 0.0-250.0 ↔ 0.0-5.0 V CT Contact enum 1 - open 0 - closed A5-14-09 (Window/Door-Sensor with States Open/Closed/Tilt, Supply voltage monitor)
shortcut description type values SVC Supply voltage / super cap. (linear) value 0.0-250.0 ↔ 0.0-5.0 V CT Contact enum 0 - Closed 1 - Tilt 2 - Reserved 3 - Open A5-14-0A (Window/Door-Sensor with States Open/Closed/Tilt, Supply voltage monitor and Vibration detection)
shortcut description type values SVC Supply voltage / super cap. (linear) value 0.0-250.0 ↔ 0.0-5.0 V CT Contact enum 0 - Closed 1 - Tilt 2 - Reserved 3 - Open VIB Vibration enum 1 - Vibration detected 0 - No vibration detected 20 (HVAC Components)
A5-20-01 (Battery Powered Actuator (BI-DIR))
shortcut description type values CV Current Value value 0.0-100.0 ↔ 0.0-100.0 % SO Service On enum 0 - off 1 - on ENIE Energy input enabled enum 0 - false 1 - true ES Energy storage sufficiently charged enum 0 - false 1 - true BCAP Battery capacity; change battery next days enum 0 - false 1 - true CCO Contact, cover open enum 0 - false 1 - true FTS Failure Temperature sensor, out of range enum 0 - false 1 - true DWO Detection, window open enum 0 - false 1 - true ACO Actuator obstructed enum 0 - false 1 - true TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-40.0 °C
shortcut description type values SP Valve Position or Temperature Setpoint value 0.0-100.0 ↔ 0.0-100.0 % TMP Temperature from RCU value 255.0-0.0 ↔ 0.0-40.0 °C RIN Run init sequence enum 0 - false 1 - true LFS Lift set enum 0 - false 1 - true VO Valve open / maintenance enum 0 - false 1 - true VC Valve closed enum 0 - false 1 - true SB Summer bit, Reduction of energy consumption enum 0 - false 1 - true SPS Set point selection enum 0 - Valve position 1 - Temperature set point SPN Set point inverse enum 0 - false 1 - true RCU Select function enum 0 - RCU 1 - service on A5-20-04 (Heating Radiator Valve Actuating Drive with feed and room temperature MEasurement, Local Set point and Display (BI-DIR))
shortcut description type values CP Current Value value 0.0-100.0 ↔ 0.0-100.0 % FTS Feed Temperature OR Temperature Set Point value 0.0-255.0 ↔ 0.0-255.0 TMPFC Room Temperature OR Failure Code value 0.0-255.0 ↔ 0.0-255.0 MST Measurement Status enum 0 - Active 1 - Inactive STR Status Request enum 0 - No change 1 - Status requested BLS Button Lock Status enum 0 - Unlocked 1 - Locked TS Temperature Selection enum 0 - Feed Temperature 1 - Temperature Set Point FL Failure enum 0 - No Failure 1 - Failure
shortcut description type values POS Valve Position value 0.0-100.0 ↔ 0.0-100.0 % TSP Temperature Set Point value 0.0-255.0 ↔ 10.0-30.0 °C MC Measure Control enum 0 - Enable 1 - Disable WUC Wake Up Cycle enum 0 - 10 sec 1 - 60 sec 2 - 90 sec 3 - 120 sec 4 - 150 sec 5 - 180 sec 6 - 210 sec 7 - 240 sec 8 - 270 sec 9 - 300 sec 10 - 330 sec 11 - 360 sec 12 - 390 sec 13 - 420 sec 14 - 450 sec 15 - 480 sec 16 - 510 sec 17 - 540 sec 18 - 570 sec 19 - 600 sec 20 - 630 sec 21 - 660 sec 22 - 690 sec 23 - 720 sec 24 - 750 sec 25 - 780 sec 26 - 810 sec 27 - 840 sec 28 - 870 sec 29 - 900 sec 30 - 930 sec 31 - 960 sec 32 - 990 sec 33 - 1020 sec 34 - 1050 sec 35 - 1080 sec 36 - 1110 sec 37 - 1140 sec 38 - 1170 sec 39 - 1200 sec 40 - 1230 sec 41 - 1260 sec 42 - 1290 sec 43 - 1320 sec 44 - 1350 sec 45 - 1380 sec 46 - 1410 sec 47 - 1440 sec 48 - 1470 sec 49 - 1500 sec 50 - 3 hrs 51 - 6 hrs 52 - 9 hrs 53 - 12 hrs 54 - 15 hrs 55 - 18 hrs 56 - 21 hrs 57 - 24 hrs 58 - 27 hrs 59 - 30 hrs 60 - 33 hrs 61 - 36 hrs 62 - 39 hrs 63 - 42 hrs (max) DSO Display Orientation enum 0 - 0° 1 - 90° 2 - 180° 3 - 270° BLC Button Lock Control enum 0 - Unlocked 1 - Locked SER Service command enum 0 - No change 1 - Open valve 2 - Run initialisation 3 - Close valve A5-20-06 (Harvesting-powered actuator with local temperature offset control (BI-DIR))
shortcut description type values CV Current Valve position value 0.0-100.0 ↔ 0.0-100.0 % LOM Local Offset Mode enum 0 - LO is relative 1 - LO is absolute LO Local Offset value 0.0-127.0 ↔ 0.0-127.0 °C TMP Local Ambient or Feed temperature value 0.0-255.0 ↔ 0.0-255.0 °C TSL Indicates which sensor is used for TMP enum 0 - Ambient sensor temp 1 - Feed sensor temperature ENIE Harvesting status enum 0 - Not harvesting 1 - Harvesting active ES Charge level of energy storage enum 0 - Low, almost discharged 1 - Sufficiently charged DWO Window open detection enum 0 - No open window detected 1 - Open window detected RCE Indicates radio communication errors enum 0 - Radio communication is stable 1 - Six or more consecutive radio communication errors have occurred RSS Weak radio signal warning enum 0 - Radio signal is strong 1 - Radio signal is weak (-77 dBm or less) ACO Reports blocked actuator (motor) enum 0 - Actuator working correctly 1 - Actuator is blocked
shortcut description type values SP Valve Position or Temperature Set point value 0.0-255.0 ↔ 0.0-255.0 % TMP Room temperature from room control unit value 0.0-160.0 ↔ 0.0-40.0 °C REF Execute reference-run enum 0 - Normal operation 1 - Reference-run and Maintenance Interval RFC Radio duty cycle selection. enum 0 - AUTO (default) 1 - 2 minutes 2 - 5 minutes 3 - 10 minutes 4 - 20 minutes 5 - 30 minutes 6 - 60 minutes 7 - 120 minutes SB Initiate summer mode (reduced communication) enum 0 - Normal operation 1 - Summer mode with 8h radio duty cycle SPS Set point selection for DB3 enum 0 - Valve position mode 1 - Temperature set point TSL Temperature requested from the actuator enum 0 - Request ambient temperature 1 - Request feed temperature SBY Enter standby mode, refer to Appendix enum 0 - Normal operation 1 - Standby 30 (Digital Input)
A5-30-03 (4 Digital Inputs, Wake and Temperature)
shortcut description type values TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C WA0 Value of wake signal enum 0 - Low 1 - High DI3 Digital Input 3 enum 0 - Low 1 - High DI2 Digital Input 2 enum 0 - Low 1 - High DI1 Digital Input 1 enum 0 - Low 1 - High DI0 Digital Input 0 enum 0 - Low 1 - High A5-30-04 (3 Digital Inputs, 1 Digital Input 8 bits)
shortcut description type values DV0 Digital Value 1 byte value 0.0-255.0 ↔ 0.0-255.0 DI2 Digital Input 2 enum 0 - Low 1 - High DI1 Digital Input 1 enum 0 - Low 1 - High DI0 Digital Input 0 enum 0 - Low 1 - High 38 (Central Command)
A5-38-08 (Gateway)
shortcut description type values COM Command ID enum 0-13 - Command ID {value} TIM Time in 1/10 seconds. 0 = no time specifed value 1.0-65535.0 ↔ 0.1-6553.5 s LCK Lock for duration time if time >0, unlimited time of no time specified. Locking may be cleared with "unlock". During lock phase no other commands will be accepted or executed enum 0 - Unlock 1 - Lock DEL Delay or duration (if Time > 0); 0 = Duration (Execute switching command immediately and switch back after duration) 1 = Delay (Execute switching command after delay) enum 0 - Duration 1 - Delay SW Switching command ON/OFF enum 0 - Off 1 - On
shortcut description type values COM Command ID enum 0-13 - Command ID {value} EDIM Dimming value (absolute [0...255] or relative [0...100]) value 0.0-255.0 ↔ 0.0-255.0 % RMP Ramping time in seconds, 0 = no ramping, 1...255 = seconds to 100% value 0.0-255.0 ↔ 0.0-255.0 s EDIMR Dimming Range enum 0 - Absolute value 1 - Relative value STR Store final value enum 0 - No 1 - Yes SW Switching command enum 0 - Off 1 - On 3F (Universal)
A5-3F-7F (Universal)
shortcut description type values DB3 Data Byte 3 value 0.0-255.0 ↔ 0.0-255.0 DB2 Data Byte 2 value 0.0-255.0 ↔ 0.0-255.0 DB1 Data Byte 1 value 0.0-255.0 ↔ 0.0-255.0 DB0 Data Byte 0 value 0.0-255.0 ↔ 0.0-255.0
D2 (VLD Telegram)
01 (Electronic switches and dimmers with Energy Measurement and Local Control)
D2-01-01 (Electronic switch with Local Control)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set D2-01-08 (Type 0x08)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} RM Report measurement enum 0 - Query only 1 - Query / auto RE Reset measurement enum 0 - Not active 1 - Trigger signal ep Measurement mode enum 0 - Energy 1 - Power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value} MAT Max message time enum 0 - Reserved 1-255 - Max message time {value} MIT Min message time enum 0 - Reserved 1-255 - Min message time {value}
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} qu Query enum 0 - Query energy 1 - Query power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MV Measurement value enum 0-4294967295 - Measurement value {value} D2-01-09 (Type 0x09)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} RM Report measurement enum 0 - Query only 1 - Query / auto RE Reset measurement enum 0 - Not active 1 - Trigger signal ep Measurement mode enum 0 - Energy 1 - Power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value} MAT Max message time enum 0 - Reserved 1-255 - Max message time {value} MIT Min message time enum 0 - Reserved 1-255 - Min message time {value}
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} qu Query enum 0 - Query energy 1 - Query power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MV Measurement value enum 0-4294967295 - Measurement value {value} D2-01-0A (Smart Plug module, no metering capabilities)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set D2-01-0B (Smart Plug module with Energy Measurement)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} RM Report measurement enum 0 - Query only 1 - Query / auto RE Reset measurement enum 0 - Not active 1 - Trigger signal ep Measurement mode enum 0 - Energy 1 - Power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value} MAT Max message time enum 0 - Reserved 1-255 - Max message time {value} MIT Min message time enum 0 - Reserved 1-255 - Min message time {value}
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} qu Query enum 0 - Query energy 1 - Query power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MV Measurement value enum 0-4294967295 - Measurement value {value} D2-01-0C (Heating module with Pilotwire command and Energy Measurement)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} RM Report measurement enum 0 - Query only 1 - Query / auto RE Reset measurement enum 0 - Not active 1 - Trigger signal ep Measurement mode enum 0 - Energy 1 - Power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value} MAT Max message time enum 0 - Reserved 1-255 - Max message time {value} MIT Min message time enum 0 - Reserved 1-255 - Min message time {value}
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} qu Query enum 0 - Query energy 1 - Query power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MV Measurement value enum 0-4294967295 - Measurement value {value}
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} PM Pilotwire mode enum 0 - Off 1 - Comfort 2 - Eco 3 - Anti-freeze 4 - Comfort-1 5 - Comfort-2
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value}
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} PM Pilotwire mode enum 0 - Off 1 - Comfort 2 - Eco 3 - Anti-freeze 4 - Comfort-1 5 - Comfort-2 D2-01-0D (Micro Smart Plug module with 1 channel, no metering capabilities)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set D2-01-0E (Micro Smart Plug module with 1 channel, and metering capabilities)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} RM Report measurement enum 0 - Query only 1 - Query / auto RE Reset measurement enum 0 - Not active 1 - Trigger signal ep Measurement mode enum 0 - Energy 1 - Power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value} MAT Max message time enum 0 - Reserved 1-255 - Max message time {value} MIT Min message time enum 0 - Reserved 1-255 - Min message time {value}
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} qu Query enum 0 - Query energy 1 - Query power IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} UN Unit enum 0 - Energy [Ws] 1 - Energy [Wh] 2 - Energy [KWh] 3 - Power [W] 4 - Power [KW] 5-7 - Not used IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) MV Measurement value enum 0-4294967295 - Measurement value {value} D2-01-0F (Slot-in Module with 1 channel, no metering capabilities)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set D2-01-12 (Slot-in Module with 2 channels, no metering capabilities)
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} DV Dim value enum 0 - Switch to new output value 1 - Dim to new output level - dim timer 1 2 - Dim to new output level - dim timer 2 3 - Dim to new output level - dim timer 3 4 - Stop dimming IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply) OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set
shortcut description type values CMD Command identifier enum 0-13 - Command ID {value} IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - All output channels supported by the device 31 - Input channel (from mains supply)
shortcut description type values PF Power Failure enum 0 - Power Failure Detection disabled/not supported 1 - Power Failure Detection enabled PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled 1 - Power Failure Detected CMD Command identifier enum 0-13 - Command ID {value} OC Over current switch off enum 0 - Over current switch off: ready / not supported 1 - Over current switch off: executed EL Error level enum 0 - Error level 0: hardware OK 1 - Error level 1: hardware warning 2 - Error level 2: hardware failure 3 - Error level not supported IO I/O channel enum 0-29 - Output channel {value} (to load) 30 - Not applicable, do not use 31 - Input channel (from mains supply) LC Local control enum 0 - Local control disabled / not supported 1 - Local control enabled OV Output value enum 0 - Output value 0% or OFF 1-100 - Output value {value}% or ON 101-126 - Not used 127 - output value not valid / not set 03 (Light, Switching + Blind Control)
D2-03-0A (Push Button – Single Button)
shortcut description type values BATT Battery Autonomy value 1.0-100.0 ↔ 1.0-100.0 % BA Button Action enum 0 - Reserved 1 - Simple press 2 - Double press 3 - Long press 4 - Long press released 5-255 - Reserved 05 (Blinds Control for Position and Angle)
D2-05-00 (Type 0x00)
shortcut description type values POS Vertical position enum 0-100 - Output position {value}% 127 - Do not change ANG Rotation angle enum 0-100 - Output angle {value}% 127 - Do not change REPO Repositioning enum 0 - Go directly to POS/ANG 1 - Go up (0%), then to POS/ANG 2 - Go down (100%), then to POS/ANG 3 - Reserved LOCK Locking modes enum 0 - Do not change 1 - Set blockage mode 2 - Set alarm mode 3 - Reserved 4 - Reserved 5 - Reserved 6 - Reserved 7 - Deblockage CHN Channel enum 0 - Channel 1 CMD Command Id enum 0-5 - Command ID {value}
shortcut description type values CHN Channel enum 0 - Channel 1 CMD Command Id enum 0-5 - Command ID {value}
shortcut description type values CHN Channel enum 0 - Channel 1 CMD Command Id enum 0-5 - Command ID {value}
shortcut description type values POS Current vertical position enum 0-100 - Output position {value}% 127 - Position unknown, will be known after the next goto cmd ANG Current rotation angle enum 0-100 - Output angle {value}% 127 - Angle unknown, will be known after the next goto cmd LOCK Current locking mode enum 0 - Normal (no lock) 1 - Blockage mode 2 - Alarm mode 3 - Reserved 4 - Reserved 5 - Reserved 6 - Reserved 7 - Reserved CHN Channel enum 0 - Channel 1 1 - Channel 2 2 - Channel 3 3 - Channel 4 CMD Command Id enum 0-5 - Command ID {value} D2-05-02 (Type 0x02)
shortcut description type values POS Vertical position enum 0-100 - Output position {value}% 127 - Do not change ANG Rotation angle enum 0-100 - Output angle {value}% 127 - Do not change REPO Repositioning enum 0 - Go directly to POS/ANG 1 - Go up (0%), then to POS/ANG 2 - Go down (100%), then to POS/ANG 3 - Reserved LOCK Locking modes enum 0 - Do not change 1 - Set blockage mode 2 - Reserved 3 - Reserved 4 - Reserved 5 - Reserved 6 - Reserved 7 - Deblockage CHN Channel enum 0 - Channel 1 1-15 - Reserved {value} CMD Command Id enum 0 - Reserved 1-4 - Command ID {value} 5-15 - Reserved {value}
shortcut description type values CHN Channel enum 0 - Channel 1 1-15 - Reserved {value} CMD Command Id enum 0 - Reserved 1-4 - Command ID {value} 5-15 - Reserved {value}
shortcut description type values CHN Channel enum 0 - Channel 1 1-15 - Reserved {value} CMD Command Id enum 0 - Reserved 1-4 - Command ID {value} 5-15 - Reserved {value}
shortcut description type values POS Current vertical position enum 0-100 - Output position {value}% 127 - Position unknown, will be known after the next goto cmd ANG Current rotation angle enum 0-100 - Output angle {value}% 127 - Angle unknown, will be known after the next goto cmd LOCK Current locking mode enum 0 - Normal (no lock) 1 - Blockage mode 2 - Reserved 3 - Reserved 4 - Reserved 5 - Reserved 6 - Reserved 7 - Reserved CHN Channel enum 0 - Channel 1 1-15 - Reserved {value} CMD Command Id enum 0 - Reserved 1-4 - Command ID {value} 5-15 - Reserved {value} 14 (Multi Function Sensors)
D2-14-30 (Sensor for Smoke, Air quality, Hygrothermal comfort, Temperature and Humidity)
shortcut description type values SMA0 Smoke Alarm status enum 0 - Smoke Alarm non-activated 1 - Smoke Alarm activated SMA1 Sensor fault mode status enum 0 - Sensor Fault mode non-activated 1 - Sensor Fault mode activated SMA2 Smoke Alarm Condition analysis: Maintenance enum 0 - Maintenance OK 1 - Maintenance not done SMA3 Smoke Alarm Condition analysis: Humidity enum 0 - Humidity range OK 1 - Humidity range NOK SMA4 Smoke Alarm Condition analysis: Temperature enum 0 - Temperature range OK 1 - Temperature range NOK SMA5 Time since last maintenance enum 0-250 - {value} week(s) 251-254 - Reserved 255 - Error ES Energy Storage Status enum 0 - High 1 - Medium 2 - Low 3 - Critical RPLT Countdown time until product end of life enum 0-120 - {value} month(s) 121-254 - Reserved 255 - Error TMP8 Temperature value 0.0-250.0 ↔ 0.0-50.0 °C HUM Humidity value 0.0-200.0 ↔ 0.0-100.0 % HCI Hygrothermal Comfort Index enum 0 - Good 1 - Medium 2 - Bad 3 - Error IAQTH T/Hum. Indoor Air Analysis enum 0 - Optimal air range 1 - Dry Air range 2 - High humidity range 3 - High temperature and humidity range 4 - Temperature or Humidity out of analysis range 5-6 - Reserved 7 - Error D2-14-41 (Indoor -Temperature, Humidity XYZ Acceleration, Illumination Sensor)
shortcut description type values TMP Temperature 10 value 0.0-1000.0 ↔ -40.0-60.0 °C HUM Rel. Humidity (linear) value 0.0-200.0 ↔ 0.0-100.0 % ILL Illumination (linear) value 0.0-100000.0 ↔ 0.0-100000.0 lx ACC Acceleration Status enum 0 - Periodic Update 1 - Threshold 1 exceeded 2 - Threshold 2 exceeded ACX Absolute Acceleration on X axis value 0.0-1000.0 ↔ -2.5-2.5 g ACY Absolute Acceleration on Y axis value 0.0-1000.0 ↔ -2.5-2.5 g ACZ Absolute Acceleration on Z axis value 0.0-1000.0 ↔ -2.5-2.5 g CO Contact enum 0 - Open 1 - Closed 50 (Heat Recovery Ventilation)
D2-50-00 (Type 0x00 (single room ventilation unit))
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} RMT Requested Message Type enum 0 - Ventilation basic status 1 - Ventilation extended status
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} DOMC Direct Operation Mode Control enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - No action (keep current ventilation mode/level) OMC Operation Mode Control enum 0 - No action 1 - Select next operation mode (edge-trigger) 2 - Select previous operation mode (edge-trigger) 3 - Reserved TOMC Timer Operation Mode Control enum 0 - No action 1 - Start timer operation mode (edge-trigger) COT CO2 Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) HT Humidity Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) AQT Air Quality Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device)
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} OMS Operation Mode Status enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - Reserved SFP Supply Air Flap Position enum 0 - Supply air flap closed 1 - Supply air flap opened EFP Exhaust Air Flap Position enum 0 - Exhaust air flap closed 1 - Exhaust air flap opened DMS Defrost Mode Status enum 0 - Defrost mode inactive 1 - Defrost mode active CPS Cooling Protection Status enum 0 - Cooling protection mode inactive 1 - Cooling protection mode active DHS Drain Heater Status enum 0 - Inactive 1 - Active TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive 1 - timer operation mode active FMS Filter Maintenance Status enum 0 - Maintenance not required 1 - Maintenance required AQS1 Air Quality Sensor 1 enum 0-100 - {value} % 101-126 - Reserved 127 - Not available MSS Master/Slave Configuration Status enum 0 - Master 1 - Slave OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0 OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0 IMS Info Message 0...15 Status enum 0-65535 - {value} FS Fault 0...31 Status enum 0-4294967295 - {value} D2-50-01 (Type 0x01 (single room ventilation unit with pre-heater))
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} RMT Requested Message Type enum 0 - Ventilation basic status 1 - Ventilation extended status
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} DOMC Direct Operation Mode Control enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - No action (keep current ventilation mode/level) OMC Operation Mode Control enum 0 - No action 1 - Select next operation mode (edge-trigger) 2 - Select previous operation mode (edge-trigger) 3 - Reserved TOMC Timer Operation Mode Control enum 0 - No action 1 - Start timer operation mode (edge-trigger) COT CO2 Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) HT Humidity Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) AQT Air Quality Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device)
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} OMS Operation Mode Status enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - Reserved SFP Supply Air Flap Position enum 0 - Supply air flap closed 1 - Supply air flap opened EFP Exhaust Air Flap Position enum 0 - Exhaust air flap closed 1 - Exhaust air flap opened DMS Defrost Mode Status enum 0 - Defrost mode inactive 1 - Defrost mode active CPS Cooling Protection Status enum 0 - Cooling protection mode inactive 1 - Cooling protection mode active OHS Outdoor Air Heater Status enum 0 - Inactive 1 - Active DHS Drain Heater Status enum 0 - Inactive 1 - Active TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive 1 - timer operation mode active FMS Filter Maintenance Status enum 0 - Maintenance not required 1 - Maintenance required AQS1 Air Quality Sensor 1 enum 0-100 - {value} % 101-126 - Reserved 127 - Not available MSS Master/Slave Configuration Status enum 0 - Master 1 - Slave OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0 OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0 IMS Info Message 0...15 Status enum 0-65535 - {value} FS Fault 0...31 Status enum 0-4294967295 - {value} D2-50-10 (Type 0x10 (multi room ventilation unit without bypass))
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} RMT Requested Message Type enum 0 - Ventilation basic status 1 - Ventilation extended status
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} DOMC Direct Operation Mode Control enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - No action (keep current ventilation mode/level) OMC Operation Mode Control enum 0 - No action 1 - Select next operation mode (edge-trigger) 2 - Select previous operation mode (edge-trigger) 3 - Reserved TOMC Timer Operation Mode Control enum 0 - No action 1 - Start timer operation mode (edge-trigger) COT CO2 Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) HT Humidity Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) AQT Air Quality Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) RTT Room temperature threshold value 1.0-127.0 ↔ -63.0-63.0 °C
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} OMS Operation Mode Status enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - Reserved DMS Defrost Mode Status enum 0 - Defrost mode inactive 1 - Defrost mode active CPS Cooling Protection Status enum 0 - Cooling protection mode inactive 1 - Cooling protection mode active OHS Outdoor Air Heater Status enum 0 - Inactive 1 - Active SHS Supply Air Heater Status enum 0 - Inactive 1 - Active TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive 1 - timer operation mode active FMS Filter Maintenance Status enum 0 - Maintenance not required 1 - Maintenance required WTPS Weekly Timer Program Status enum 0 - Weekly timer program disabled or not configured 1 - Weekly timer program active RTCS Room Temperature Control Status enum 0 - Room temperature control inactive 1 - Room temperature control active AQS1 Air Quality Sensor 1 enum 0-100 - {value} % 101-126 - Reserved 127 - Not available AQS2 Air Quality Sensor 2 enum 0-100 - {value} % 101-126 - Reserved 127 - Not available OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C INT Indoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C EXHT Exhaust Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0 OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0 DIS Digital Input 0...15 Status enum 0-65535 - {value} DOS Digital Output 0...15 Status enum 0-65535 - {value} IMS Info Message 0...15 Status enum 0-65535 - {value} FS Fault 0...31 Status enum 0-4294967295 - {value} D2-50-11 (Type 0x11 (multi room ventilation unit with bypass))
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} RMT Requested Message Type enum 0 - Ventilation basic status 1 - Ventilation extended status
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} DOMC Direct Operation Mode Control enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - No action (keep current ventilation mode/level) OMC Operation Mode Control enum 0 - No action 1 - Select next operation mode (edge-trigger) 2 - Select previous operation mode (edge-trigger) 3 - Reserved HBC Heat Exchanger Bypass Control enum 0 - No action 1 - Close bypass (edge-trigger) 2 - Open bypass (edge-trigger) 3 - Reserved TOMC Timer Operation Mode Control enum 0 - No action 1 - Start timer operation mode (edge-trigger) COT CO2 Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) HT Humidity Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) AQT Air Quality Threshold enum 0-100 - {value} % 101-126 - Reserved 127 - Default (use threshold configured in device) RTT Room temperature threshold value 1.0-127.0 ↔ -63.0-63.0 °C
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} OMS Operation Mode Status enum 0 - Off 1 - Level 1 2 - Level 2 3 - Level 3 4 - Level 4 5-10 - Reserved 11 - Automatic 12 - Automatic on demand 13 - Supply air only 14 - Exhaust air only 15 - Reserved SMS Safety Mode Status enum 0 - Fireplace safety mode disabled 1 - Fireplace safety mode enabled HBS Heat Exchanger Bypass Status enum 0 - Bypass closed (heat-recovery active) 1 - Bypass opened (heat-recovery inactive) DMS Defrost Mode Status enum 0 - Defrost mode inactive 1 - Defrost mode active CPS Cooling Protection Status enum 0 - Cooling protection mode inactive 1 - Cooling protection mode active OHS Outdoor Air Heater Status enum 0 - Inactive 1 - Active SHS Supply Air Heater Status enum 0 - Inactive 1 - Active TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive 1 - timer operation mode active FMS Filter Maintenance Status enum 0 - Maintenance not required 1 - Maintenance required WTPS Weekly Timer Program Status enum 0 - Weekly timer program disabled or not configured 1 - Weekly timer program active RTCS Room Temperature Control Status enum 0 - Room temperature control inactive 1 - Room temperature control active AQS1 Air Quality Sensor 1 enum 0-100 - {value} % 101-126 - Reserved 127 - Not available AQS2 Air Quality Sensor 2 enum 0-100 - {value} % 101-126 - Reserved 127 - Not available OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C INT Indoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C EXHT Exhaust Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
shortcut description type values MT Message Type enum 0-3 - Message Type {value} 4-7 - Reserved {value} SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0 OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0 DIS Digital Input 0...15 Status enum 0-65535 - {value} DOS Digital Output 0...15 Status enum 0-65535 - {value} IMS Info Message 0...15 Status enum 0-65535 - {value} FS Fault 0...31 Status enum 0-4294967295 - {value}