Supported profiles

All profiles (should) correspond to the official EEP by EnOcean.

F6 (RPS Telegram)
01 (Switch Buttons)
F6-01-01 (Push Button)
shortcut description type values
PB Status of the push button enum 0 - Released
1 - Pressed
02 (Rocker Switch, 2 Rocker)
F6-02-01 (Light and Blind Control - Application Style 1)
shortcut description type values
R1 Rocker 1st action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
EB Energy bow enum 0 - released
1 - pressed
R2 Rocker 2nd action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
SA 2nd action enum 0 - No 2nd action
1 - 2nd action valid
T21 T21 status
NU NU status
F6-02-02 (Light and Blind Control - Application Style 2)
shortcut description type values
R1 Rocker 1st action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
EB Energy bow enum 0 - released
1 - pressed
R2 Rocker 2nd action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
SA 2nd action enum 0 - No 2nd action
1 - 2nd action valid
T21 T21 status
NU NU status
04 (Position Switch, Home and Office Application)
F6-04-01 (Key Card Activated Switch)
shortcut description type values
KC Key Card enum 0 - Taken out
112 - Inserted
T21 T21 status
NU NU status
05 (Detectors)
F6-05-01 (Liquid Leakage Sensor (mechanic harvester))
shortcut description type values
WAS Water Sensor enum 0-16 - not specified
17 - Water detected
18-255 - not specified
T21 T21 status
NU NU status
F6-05-02 (Smoke Detector)
shortcut description type values
SMO Status of detection and battery enum 0 - Smoke Alarm OFF
16 - Smoke Alarm ON
48 - Energy LOW
10 (Mechanical Handle)
F6-10-00 (Window Handle)
shortcut description type values
WIN Window handle enum 0 - Moved from up to vertical
1 - Moved from vertical to up
2 - Moved from down to vertical
3 - Moved from vertical to down
T21 T21 status
NU NU status
D5 (1BS Telegram)
00 (Contacts and Switches)
D5-00-01 (Single Input Contact)
shortcut description type values
CO Contact enum 0 - open
1 - closed
A5 (4BS Telegram)
02 (Temperature Sensors)
A5-02-01 (Temperature Sensor Range -40°C to 0°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -40.0-0.0 °C
A5-02-02 (Temperature Sensor Range -30°C to +10°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -30.0-10.0 °C
A5-02-03 (Temperature Sensor Range -20°C to +20°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -20.0-20.0 °C
A5-02-04 (Temperature Sensor Range -10°C to +30°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -10.0-30.0 °C
A5-02-05 (Temperature Sensor Range 0°C to +40°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
A5-02-06 (Temperature Sensor Range +10°C to +50°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 10.0-50.0 °C
A5-02-07 (Temperature Sensor Range +20°C to +60°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 20.0-60.0 °C
A5-02-08 (Temperature Sensor Range +30°C to +70°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 30.0-70.0 °C
A5-02-09 (Temperature Sensor Range +40°C to +80°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 40.0-80.0 °C
A5-02-0A (Temperature Sensor Range +50°C to +90°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 50.0-90.0 °C
A5-02-0B (Temperature Sensor Range +60°C to +100°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 60.0-100.0 °C
A5-02-10 (Temperature Sensor Range -60°C to +20°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -60.0-20.0 °C
A5-02-11 (Temperature Sensor Range -50°C to +30°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -50.0-30.0 °C
A5-02-12 (Temperature Sensor Range -40°C to +40°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -40.0-40.0 °C
A5-02-13 (Temperature Sensor Range -30°C to +50°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -30.0-50.0 °C
A5-02-14 (Temperature Sensor Range -20°C to +60°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -20.0-60.0 °C
A5-02-15 (Temperature Sensor Range -10°C to +70°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -10.0-70.0 °C
A5-02-16 (Temperature Sensor Range 0°C to +80°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-80.0 °C
A5-02-17 (Temperature Sensor Range +10°C to +90°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 10.0-90.0 °C
A5-02-18 (Temperature Sensor Range +20°C to +100°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 20.0-100.0 °C
A5-02-19 (Temperature Sensor Range +30°C to +110°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 30.0-110.0 °C
A5-02-1A (Temperature Sensor Range +40°C to +120°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 40.0-120.0 °C
A5-02-1B (Temperature Sensor Range +50°C to +130°C)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 50.0-130.0 °C
A5-02-20 (10 Bit Temperature Sensor Range -10°C to +41.2°C)
shortcut description type values
TMP Temperature (linear) value 1023.0-0.0 ↔ -10.0-41.2 °C
A5-02-30 (10 Bit Temperature Sensor Range -40°C to +62.3°C)
shortcut description type values
TMP Temperature (linear) value 1023.0-0.0 ↔ -40.0-62.3 °C
04 (Temperature and Humidity Sensor)
A5-04-01 (Range 0°C to +40°C and 0% to 100%)
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C
TSN Availability of the Temperature Sensor enum 0 - not available
1 - available
A5-04-02 (Range -20°C to +60°C and 0% to 100%)
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-250.0 ↔ -20.0-60.0 °C
TSN Availability of the Temperature Sensor enum 0 - not available
1 - available
A5-04-03 (Range -20°C to +60°C 10bit-measurement and 0% to 100%)
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-255.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-1023.0 ↔ -20.0-60.0 °C
TTP Telegram Type enum 0 - Heartbeat
1 - Event triggered
A5-04-04 (Range -40°C to +120°C 12bit-measurement and 0% to 100%)
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-199.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-1599.0 ↔ -40.0-120.0 °C
06 (Light Sensor)
A5-06-01 (Range 300lx to 60.000lx)
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL2 Illumination 2 (linear) value 0.0-255.0 ↔ 300.0-30000.0 lx
ILL1 Illumination 1 (linear) value 0.0-255.0 ↔ 600.0-60000.0 lx
RS Range select enum 0 - Range acc. to DB_1 (ILL1)
1 - Range acc. to DB_2 (ILL2)
A5-06-02 (Range 0lx to 1.020lx)
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL2 Illumination 2 (linear) value 0.0-255.0 ↔ 0.0-510.0 lx
ILL1 Illumination 1 (linear) value 0.0-255.0 ↔ 0.0-1020.0 lx
RS Range select enum 0 - Range acc. to DB_1 (ILL1)
1 - Range acc. to DB_2 (ILL2)
07 (Occupancy Sensor)
A5-07-01 (Occupancy with Supply voltage monitor)
shortcut description type values
SVC Supply voltage (OPTIONAL) value 0.0-250.0 ↔ 0.0-5.0 V
PIRS PIR Status enum 0 - PIR off
1 - PIR on
SVA Supply voltage availability enum 0 - Supply voltage is not supported
1 - Supply voltage is supported
A5-07-02 (Occupancy with Supply voltage monitor)
shortcut description type values
SVC Supply voltage (REQUIRED) value 0.0-250.0 ↔ 0.0-5.0 V
PIRS PIR Status enum 0 - Uncertain of occupancy status
1 - Motion detected
A5-07-03 (Occupancy with Supply voltage monitor)
shortcut description type values
SVC Supply voltage (REQUIRED) value 0.0-250.0 ↔ 0.0-5.0 V
ILL Illumination value 0.0-1000.0 ↔ 0.0-1000.0 lx
PIRS PIR Status enum 0 - Uncertain of occupancy status
1 - Motion detected
08 (Light, Temperature and Occupancy Sensor)
A5-08-01 (Range 0lx to 510lx, 0°C to +51°C and Occupancy Button)
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL Illumination (linear) value 0.0-255.0 ↔ 0.0-510.0 lx
TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C
PIRS PIR Status enum 0 - PIR on
1 - PIR off
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
A5-08-02 (Range 0lx to 1020lx, 0°C to +51°C and Occupancy Button)
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL Illumination (linear) value 0.0-255.0 ↔ 0.0-1020.0 lx
TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C
PIRS PIR Status enum 0 - PIR on
1 - PIR off
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
A5-08-03 (Range 0lx to 1530lx, -30°C to +51°C and Occupancy Button)
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL Illumination (linear) value 0.0-255.0 ↔ 0.0-1530.0 lx
TMP Temperature (linear) value 0.0-255.0 ↔ -30.0-50.0 °C
PIRS PIR Status enum 0 - PIR on
1 - PIR off
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
09 (Gas Sensor)
A5-09-04 (CO2 Sensor)
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-200.0 ↔ 0.0-100.0 %
Conc Concentration (linear) value 0.0-255.0 ↔ 0.0-2550.0 ppm
TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C
HSN Availability of the Humidity Sensor enum 0 - not available
1 - available
TSN Availability of the Temperature Sensor enum 0 - not available
1 - available
A5-09-05 (VOC Sensor)
shortcut description type values
Conc VOC Concentration value 0.0-65535.0 ↔ 0.0-65535.0 ppb
VOC_ID VOC Identification enum 0 - VOCT (total)
1 - Formaldehyde
2 - Benzene
3 - Styrene
4 - Toluene
5 - Tetrachloroethylene
6 - Xylene
7 - n-Hexane
8 - n-Octane
9 - Cyclopentane
10 - Methanol
11 - Ethanol
12 - 1-Pentanol
13 - Acetone
14 - ethylene Oxide
15 - Acetaldehyde ue
16 - Acetic Acid
17 - Propionice Acid
18 - ValericAcid
19 - ButyricAcid
20 - Ammoniac
22 - Hydrogen Sulfide
23 - Dimethylsulfide
24 - 2-Butanol (butyl Alcohol)
25 - 2-Methylpropanol
26 - Diethyl ether
255 - ozone
10 (Room Operating Panel)
A5-10-03 (Temperature Sensor and Set Point)
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
A5-10-05 (Temperature Sensor, Set Point and Occupancy Control)
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
A5-10-06 (Temperature Sensor, Set Point and Day/Night Control)
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
SLSW Slide switch enum 0 - Position I / Night / Off
1 - Position O / Day / On
A5-10-10 (Temperature and Humidity Sensor, Set Point and Occupancy Control)
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0
HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
A5-10-12 (Temperature and Humidity Sensor and Set Point)
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0
HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C
11 (Controller Status)
A5-11-02 (Temperature Controller Output)
shortcut description type values
CVAR Actual value of controller value 0.0-255.0 ↔ 0.0-100.0 %
FAN Actual value of fan enum 0 - State 0 Manual
1 - State 1 Manual
2 - State 2 Manual
3 - State 3 Manual
16 - State 0 Automatic
17 - State 1 Automatic
18 - State 2 Automatic
19 - State 3 Automatic
255 - Not Available
ASP Actual Setpoint value 0.0-255.0 ↔ 0.0-51.2 C
ALR Alarm enum 0 - No alarm
1 - Alarm
CTM Controller mode enum 1 - Heating
2 - Cooling
3 - Off
CTS Controller state enum 0 - Automatic
1 - Override
ERH Energy hold-off enum 0 - Normal
1 - Energy hold-off / Dew point
RO Room occupancy enum 0 - Occupied
1 - Unoccupied
2 - StandBy
3 - Frost
A5-11-03 (Blind Status)
shortcut description type values
BSP Blind/shutter position value 0.0-100.0 ↔ 0.0-100.0 %
AS Angle sign enum 0 - Positive sign
1 - Negative sign
AN Angle in 2 degrees steps value 0.0-90.0 ↔ 0.0-180.0 degrees
PVF Position value flag enum 0 - No position value available
1 - Position value available
AVF Angle value flag enum 0 - No Angle value available
1 - Angle value available
ES Error state enum 0 - No error present
1 - End-positions are not configured
2 - Internal failure
3 - Not used
EP End position enum 0 - No End-position available
1 - No End-position reached
2 - Blind fully open
3 - Blind fully closed
ST Status enum 0 - No status available
1 - Blind is stopped
2 - Blind opens
3 - Blind closes
SM Service mode enum 0 - Normal mode
1 - Service mode activated
MOTP Mode of the position enum 0 - Normal mode
1 - Inverse ode
12 (Automated Meter Reading (AMR))
A5-12-00 (Counter)
shortcut description type values
MR Current value in or cumulative counter value value 0.0-16777215.0 ↔ 0.0-16777215.0
CH Measurement channel value 0.0-15.0 ↔ 0.0-15.0
DT Current value or cumulative counter value enum 0 - Cumulative value
1 - Current value
DIV Divisor for value enum 0 - x/1
1 - x/10
2 - x/100
3 - x/1000
A5-12-01 (Electricity)
shortcut description type values
MR current value in W or cumulative value in kWh value 0.0-16777215.0 ↔ 0.0-16777215.0
TI Tariff info value 0.0-15.0 ↔ 0.0-15.0
DT Current value or cumulative value enum 0 - kWh
1 - W
DIV Divisor for value enum 0 - x/1
1 - x/10
2 - x/100
3 - x/1000
13 (Environmental Applications)
A5-13-01 (Weather Station)
command: 1
shortcut description type values
DWS Dawn sensor value 0.0-255.0 ↔ 0.0-999.0 lx
TMP Outdoor Temp value 0.0-255.0 ↔ -40.0-80.0 °C
WND Wind speed value 0.0-255.0 ↔ 0.0-70.0 m/s
ID Identifier enum 0-15 - Identifier {value}
DN Day / Night enum 0 - Day
1 - Night
RAN Rain Indication enum 0 - No Rain
1 - Rain
command: 2
shortcut description type values
SNW Sun - West value 0.0-255.0 ↔ 0.0-150.0 klx
SNS Sun - South value 0.0-255.0 ↔ 0.0-150.0 klx
SNE Sun - East value 0.0-255.0 ↔ 0.0-150.0 klx
ID Identifier enum 0-15 - Identifier {value}
HEM Hemisphere enum 0 - North
1 - South
command: 3
shortcut description type values
DY Day value 1.0-31.0 ↔ 1.0-31.0
MTH Month value 1.0-12.0 ↔ 1.0-12.0
YR Year value 0.0-99.0 ↔ 2000.0-2099.0
ID Identifier enum 0-15 - Identifier {value}
SRC Source enum 0 - Real Time Clock
1 - GPS or equivalent (e.g. DCF77, WWV)
command: 4
shortcut description type values
WDY Weekday enum 1 - Monday
2 - Tuesday
3 - Wednesday
4 - Thursday
5 - Friday
6 - Saturday
7 - Sunday
HR Hour value 0.0-23.0 ↔ 0.0-23.0
MIN Minute value 0.0-59.0 ↔ 0.0-59.0
SEC Second value 0.0-59.0 ↔ 0.0-59.0
ID Identifier enum 0-15 - Identifier {value}
TMF Time Format enum 0 - 24 Hours
1 - 12 Hours
AMPM AM/PM enum 0 - AM
1 - PM
SRC Source enum 0 - Real Time Clock
1 - GPS or equivalent (e.g. DCF77, WWV)
command: 5
shortcut description type values
ELV Elevation value 0.0-180.0 ↔ -90.0-90.0 °
AZM Azimut value 0.0-359.0 ↔ 0.0-359.0 °
ID Identifier enum 0-15 - Identifier {value}
command: 6
shortcut description type values
LAT_MSB Latitude(MSB) value 0.0-15.0 ↔ 0.0-15.0
LOT_MSB Longitude(MSB) value 0.0-15.0 ↔ 0.0-15.0
LAT_LSB Latitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 °
LOT_LSB Longitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 °
ID Identifier enum 0-15 - Identifier {value}
A5-13-02 (Sun Intensity)
shortcut description type values
SNW Sun - West value 0.0-255.0 ↔ 0.0-150.0 klx
SNS Sun - South value 0.0-255.0 ↔ 0.0-150.0 klx
SNE Sun - East value 0.0-255.0 ↔ 0.0-150.0 klx
ID Identifier enum 0-15 - Identifier {value}
HEM Hemisphere enum 0 - North
1 - South
A5-13-03 (Date Exchange)
shortcut description type values
DY Day value 1.0-31.0 ↔ 1.0-31.0
MTH Month value 1.0-12.0 ↔ 1.0-12.0
YR Year value 0.0-99.0 ↔ 2000.0-2099.0
ID Identifier enum 0-15 - Identifier {value}
SRC Source enum 0 - Real Time Clock
1 - GPS or equivalent (e.g. DCF77, WWV)
A5-13-04 (Time and Day Exchange)
shortcut description type values
WDY Weekday enum 1 - Monday
2 - Tuesday
3 - Wednesday
4 - Thursday
5 - Friday
6 - Saturday
7 - Sunday
HR Hour value 0.0-23.0 ↔ 0.0-23.0
MIN Minute value 0.0-59.0 ↔ 0.0-59.0
SEC Second value 0.0-59.0 ↔ 0.0-59.0
ID Identifier enum 0-15 - Identifier {value}
TMF Time Format enum 0 - 24 Hours
1 - 12 Hours
AMPM AM/PM enum 0 - AM
1 - PM
SRC Source enum 0 - Real Time Clock
1 - GPS or equivalent (e.g. DCF77, WWV)
A5-13-05 (Direction Exchange)
shortcut description type values
ELV Elevation value 0.0-180.0 ↔ -90.0-90.0 °
AZM Azimut value 0.0-359.0 ↔ 0.0-359.0 °
ID Identifier enum 0-15 - Identifier {value}
A5-13-06 (Geographic Position Exchange)
shortcut description type values
LAT_MSB Latitude(MSB) value 0.0-15.0 ↔ 0.0-15.0
LOT_MSB Longitude(MSB) value 0.0-15.0 ↔ 0.0-15.0
LAT_LSB Latitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 °
LOT_LSB Longitude(LSB) value 0.0-255.0 ↔ 0.0-255.0 °
ID Identifier enum 0-15 - Identifier {value}
14 (Multi-Func Sensor)
A5-14-01 (Single Input Contact (Window/Door), Supply voltage monitor)
shortcut description type values
SVC Supply voltage / super cap. (linear); 251 - 255 reserved for error code value 0.0-250.0 ↔ 0.0-5.0 V
CT Contact enum 1 - open
0 - closed
A5-14-09 (Window/Door-Sensor with States Open/Closed/Tilt, Supply voltage monitor)
shortcut description type values
SVC Supply voltage / super cap. (linear) value 0.0-250.0 ↔ 0.0-5.0 V
CT Contact enum 0 - Closed
1 - Tilt
2 - Reserved
3 - Open
A5-14-0A (Window/Door-Sensor with States Open/Closed/Tilt, Supply voltage monitor and Vibration detection)
shortcut description type values
SVC Supply voltage / super cap. (linear) value 0.0-250.0 ↔ 0.0-5.0 V
CT Contact enum 0 - Closed
1 - Tilt
2 - Reserved
3 - Open
VIB Vibration enum 1 - Vibration detected
0 - No vibration detected
20 (HVAC Components)
A5-20-01 (Battery Powered Actuator (BI-DIR))
direction: 1
shortcut description type values
CV Current Value value 0.0-100.0 ↔ 0.0-100.0 %
SO Service On enum 0 - off
1 - on
ENIE Energy input enabled enum 0 - false
1 - true
ES Energy storage sufficiently charged enum 0 - false
1 - true
BCAP Battery capacity; change battery next days enum 0 - false
1 - true
CCO Contact, cover open enum 0 - false
1 - true
FTS Failure Temperature sensor, out of range enum 0 - false
1 - true
DWO Detection, window open enum 0 - false
1 - true
ACO Actuator obstructed enum 0 - false
1 - true
TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-40.0 °C
direction: 2
shortcut description type values
SP Valve Position or Temperature Setpoint value 0.0-100.0 ↔ 0.0-100.0 %
TMP Temperature from RCU value 255.0-0.0 ↔ 0.0-40.0 °C
RIN Run init sequence enum 0 - false
1 - true
LFS Lift set enum 0 - false
1 - true
VO Valve open / maintenance enum 0 - false
1 - true
VC Valve closed enum 0 - false
1 - true
SB Summer bit, Reduction of energy consumption enum 0 - false
1 - true
SPS Set point selection enum 0 - Valve position
1 - Temperature set point
SPN Set point inverse enum 0 - false
1 - true
RCU Select function enum 0 - RCU
1 - service on
A5-20-04 (Heating Radiator Valve Actuating Drive with feed and room temperature MEasurement, Local Set point and Display (BI-DIR))
direction: 1
shortcut description type values
CP Current Value value 0.0-100.0 ↔ 0.0-100.0 %
FTS Feed Temperature OR Temperature Set Point value 0.0-255.0 ↔ 0.0-255.0
TMPFC Room Temperature OR Failure Code value 0.0-255.0 ↔ 0.0-255.0
MST Measurement Status enum 0 - Active
1 - Inactive
STR Status Request enum 0 - No change
1 - Status requested
BLS Button Lock Status enum 0 - Unlocked
1 - Locked
TS Temperature Selection enum 0 - Feed Temperature
1 - Temperature Set Point
FL Failure enum 0 - No Failure
1 - Failure
direction: 2
shortcut description type values
POS Valve Position value 0.0-100.0 ↔ 0.0-100.0 %
TSP Temperature Set Point value 0.0-255.0 ↔ 10.0-30.0 °C
MC Measure Control enum 0 - Enable
1 - Disable
WUC Wake Up Cycle enum 0 - 10 sec
1 - 60 sec
2 - 90 sec
3 - 120 sec
4 - 150 sec
5 - 180 sec
6 - 210 sec
7 - 240 sec
8 - 270 sec
9 - 300 sec
10 - 330 sec
11 - 360 sec
12 - 390 sec
13 - 420 sec
14 - 450 sec
15 - 480 sec
16 - 510 sec
17 - 540 sec
18 - 570 sec
19 - 600 sec
20 - 630 sec
21 - 660 sec
22 - 690 sec
23 - 720 sec
24 - 750 sec
25 - 780 sec
26 - 810 sec
27 - 840 sec
28 - 870 sec
29 - 900 sec
30 - 930 sec
31 - 960 sec
32 - 990 sec
33 - 1020 sec
34 - 1050 sec
35 - 1080 sec
36 - 1110 sec
37 - 1140 sec
38 - 1170 sec
39 - 1200 sec
40 - 1230 sec
41 - 1260 sec
42 - 1290 sec
43 - 1320 sec
44 - 1350 sec
45 - 1380 sec
46 - 1410 sec
47 - 1440 sec
48 - 1470 sec
49 - 1500 sec
50 - 3 hrs
51 - 6 hrs
52 - 9 hrs
53 - 12 hrs
54 - 15 hrs
55 - 18 hrs
56 - 21 hrs
57 - 24 hrs
58 - 27 hrs
59 - 30 hrs
60 - 33 hrs
61 - 36 hrs
62 - 39 hrs
63 - 42 hrs (max)
DSO Display Orientation enum 0 - 0°
1 - 90°
2 - 180°
3 - 270°
BLC Button Lock Control enum 0 - Unlocked
1 - Locked
SER Service command enum 0 - No change
1 - Open valve
2 - Run initialisation
3 - Close valve
A5-20-06 (Harvesting-powered actuator with local temperature offset control (BI-DIR))
direction: 1
shortcut description type values
CV Current Valve position value 0.0-100.0 ↔ 0.0-100.0 %
LOM Local Offset Mode enum 0 - LO is relative
1 - LO is absolute
LO Local Offset value 0.0-127.0 ↔ 0.0-127.0 °C
TMP Local Ambient or Feed temperature value 0.0-255.0 ↔ 0.0-255.0 °C
TSL Indicates which sensor is used for TMP enum 0 - Ambient sensor temp
1 - Feed sensor temperature
ENIE Harvesting status enum 0 - Not harvesting
1 - Harvesting active
ES Charge level of energy storage enum 0 - Low, almost discharged
1 - Sufficiently charged
DWO Window open detection enum 0 - No open window detected
1 - Open window detected
RCE Indicates radio communication errors enum 0 - Radio communication is stable
1 - Six or more consecutive radio communication errors have occurred
RSS Weak radio signal warning enum 0 - Radio signal is strong
1 - Radio signal is weak (-77 dBm or less)
ACO Reports blocked actuator (motor) enum 0 - Actuator working correctly
1 - Actuator is blocked
direction: 2
shortcut description type values
SP Valve Position or Temperature Set point value 0.0-255.0 ↔ 0.0-255.0 %
TMP Room temperature from room control unit value 0.0-160.0 ↔ 0.0-40.0 °C
REF Execute reference-run enum 0 - Normal operation
1 - Reference-run and Maintenance Interval
RFC Radio duty cycle selection. enum 0 - AUTO (default)
1 - 2 minutes
2 - 5 minutes
3 - 10 minutes
4 - 20 minutes
5 - 30 minutes
6 - 60 minutes
7 - 120 minutes
SB Initiate summer mode (reduced communication) enum 0 - Normal operation
1 - Summer mode with 8h radio duty cycle
SPS Set point selection for DB3 enum 0 - Valve position mode
1 - Temperature set point
TSL Temperature requested from the actuator enum 0 - Request ambient temperature
1 - Request feed temperature
SBY Enter standby mode, refer to Appendix enum 0 - Normal operation
1 - Standby
30 (Digital Input)
A5-30-03 (4 Digital Inputs, Wake and Temperature)
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
WA0 Value of wake signal enum 0 - Low
1 - High
DI3 Digital Input 3 enum 0 - Low
1 - High
DI2 Digital Input 2 enum 0 - Low
1 - High
DI1 Digital Input 1 enum 0 - Low
1 - High
DI0 Digital Input 0 enum 0 - Low
1 - High
A5-30-04 (3 Digital Inputs, 1 Digital Input 8 bits)
shortcut description type values
DV0 Digital Value 1 byte value 0.0-255.0 ↔ 0.0-255.0
DI2 Digital Input 2 enum 0 - Low
1 - High
DI1 Digital Input 1 enum 0 - Low
1 - High
DI0 Digital Input 0 enum 0 - Low
1 - High
38 (Central Command)
A5-38-08 (Gateway)
command: 1
shortcut description type values
COM Command ID enum 0-13 - Command ID {value}
TIM Time in 1/10 seconds. 0 = no time specifed value 1.0-65535.0 ↔ 0.1-6553.5 s
LCK Lock for duration time if time >0, unlimited time of no time specified. Locking may be cleared with "unlock". During lock phase no other commands will be accepted or executed enum 0 - Unlock
1 - Lock
DEL Delay or duration (if Time > 0); 0 = Duration (Execute switching command immediately and switch back after duration) 1 = Delay (Execute switching command after delay) enum 0 - Duration
1 - Delay
SW Switching command ON/OFF enum 0 - Off
1 - On
command: 2
shortcut description type values
COM Command ID enum 0-13 - Command ID {value}
EDIM Dimming value (absolute [0...255] or relative [0...100]) value 0.0-255.0 ↔ 0.0-255.0 %
RMP Ramping time in seconds, 0 = no ramping, 1...255 = seconds to 100% value 0.0-255.0 ↔ 0.0-255.0 s
EDIMR Dimming Range enum 0 - Absolute value
1 - Relative value
STR Store final value enum 0 - No
1 - Yes
SW Switching command enum 0 - Off
1 - On
3F (Universal)
A5-3F-7F (Universal)
shortcut description type values
DB3 Data Byte 3 value 0.0-255.0 ↔ 0.0-255.0
DB2 Data Byte 2 value 0.0-255.0 ↔ 0.0-255.0
DB1 Data Byte 1 value 0.0-255.0 ↔ 0.0-255.0
DB0 Data Byte 0 value 0.0-255.0 ↔ 0.0-255.0
D2 (VLD Telegram)
01 (Electronic switches and dimmers with Energy Measurement and Local Control)
D2-01-01 (Electronic switch with Local Control)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
D2-01-08 (Type 0x08)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 5
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
RM Report measurement enum 0 - Query only
1 - Query / auto
RE Reset measurement enum 0 - Not active
1 - Trigger signal
ep Measurement mode enum 0 - Energy
1 - Power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value}
MAT Max message time enum 0 - Reserved
1-255 - Max message time {value}
MIT Min message time enum 0 - Reserved
1-255 - Min message time {value}
command: 6
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
qu Query enum 0 - Query energy
1 - Query power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 7
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MV Measurement value enum 0-4294967295 - Measurement value {value}
D2-01-09 (Type 0x09)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 5
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
RM Report measurement enum 0 - Query only
1 - Query / auto
RE Reset measurement enum 0 - Not active
1 - Trigger signal
ep Measurement mode enum 0 - Energy
1 - Power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value}
MAT Max message time enum 0 - Reserved
1-255 - Max message time {value}
MIT Min message time enum 0 - Reserved
1-255 - Min message time {value}
command: 6
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
qu Query enum 0 - Query energy
1 - Query power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 7
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MV Measurement value enum 0-4294967295 - Measurement value {value}
D2-01-0A (Smart Plug module, no metering capabilities)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
D2-01-0B (Smart Plug module with Energy Measurement)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 5
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
RM Report measurement enum 0 - Query only
1 - Query / auto
RE Reset measurement enum 0 - Not active
1 - Trigger signal
ep Measurement mode enum 0 - Energy
1 - Power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value}
MAT Max message time enum 0 - Reserved
1-255 - Max message time {value}
MIT Min message time enum 0 - Reserved
1-255 - Min message time {value}
command: 6
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
qu Query enum 0 - Query energy
1 - Query power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 7
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MV Measurement value enum 0-4294967295 - Measurement value {value}
D2-01-0C (Heating module with Pilotwire command and Energy Measurement)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 5
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
RM Report measurement enum 0 - Query only
1 - Query / auto
RE Reset measurement enum 0 - Not active
1 - Trigger signal
ep Measurement mode enum 0 - Energy
1 - Power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value}
MAT Max message time enum 0 - Reserved
1-255 - Max message time {value}
MIT Min message time enum 0 - Reserved
1-255 - Min message time {value}
command: 6
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
qu Query enum 0 - Query energy
1 - Query power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 7
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MV Measurement value enum 0-4294967295 - Measurement value {value}
command: 8
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
PM Pilotwire mode enum 0 - Off
1 - Comfort
2 - Eco
3 - Anti-freeze
4 - Comfort-1
5 - Comfort-2
command: 9
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
command: 10
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
PM Pilotwire mode enum 0 - Off
1 - Comfort
2 - Eco
3 - Anti-freeze
4 - Comfort-1
5 - Comfort-2
D2-01-0D (Micro Smart Plug module with 1 channel, no metering capabilities)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
D2-01-0E (Micro Smart Plug module with 1 channel, and metering capabilities)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 5
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
RM Report measurement enum 0 - Query only
1 - Query / auto
RE Reset measurement enum 0 - Not active
1 - Trigger signal
ep Measurement mode enum 0 - Energy
1 - Power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MD_LSB Measurement delta LSB enum 0-15 - Measurement delta LSB {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
MD_MSB Measurement delta MSB enum 0-255 - Measurement delta MSB {value}
MAT Max message time enum 0 - Reserved
1-255 - Max message time {value}
MIT Min message time enum 0 - Reserved
1-255 - Min message time {value}
command: 6
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
qu Query enum 0 - Query energy
1 - Query power
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 7
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
UN Unit enum 0 - Energy [Ws]
1 - Energy [Wh]
2 - Energy [KWh]
3 - Power [W]
4 - Power [KW]
5-7 - Not used
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
MV Measurement value enum 0-4294967295 - Measurement value {value}
D2-01-0F (Slot-in Module with 1 channel, no metering capabilities)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
D2-01-12 (Slot-in Module with 2 channels, no metering capabilities)
command: 1
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 3
shortcut description type values
CMD Command identifier enum 0-13 - Command ID {value}
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure not detected/not supported/disabled
1 - Power Failure Detected
CMD Command identifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
03 (Light, Switching + Blind Control)
D2-03-0A (Push Button – Single Button)
shortcut description type values
BATT Battery Autonomy value 1.0-100.0 ↔ 1.0-100.0 %
BA Button Action enum 0 - Reserved
1 - Simple press
2 - Double press
3 - Long press
4 - Long press released
5-255 - Reserved
05 (Blinds Control for Position and Angle)
D2-05-00 (Type 0x00)
command: 1
shortcut description type values
POS Vertical position enum 0-100 - Output position {value}%
127 - Do not change
ANG Rotation angle enum 0-100 - Output angle {value}%
127 - Do not change
REPO Repositioning enum 0 - Go directly to POS/ANG
1 - Go up (0%), then to POS/ANG
2 - Go down (100%), then to POS/ANG
3 - Reserved
LOCK Locking modes enum 0 - Do not change
1 - Set blockage mode
2 - Set alarm mode
3 - Reserved
4 - Reserved
5 - Reserved
6 - Reserved
7 - Deblockage
CHN Channel enum 0 - Channel 1
CMD Command Id enum 0-5 - Command ID {value}
command: 2
shortcut description type values
CHN Channel enum 0 - Channel 1
CMD Command Id enum 0-5 - Command ID {value}
command: 3
shortcut description type values
CHN Channel enum 0 - Channel 1
CMD Command Id enum 0-5 - Command ID {value}
command: 4
shortcut description type values
POS Current vertical position enum 0-100 - Output position {value}%
127 - Position unknown, will be known after the next goto cmd
ANG Current rotation angle enum 0-100 - Output angle {value}%
127 - Angle unknown, will be known after the next goto cmd
LOCK Current locking mode enum 0 - Normal (no lock)
1 - Blockage mode
2 - Alarm mode
3 - Reserved
4 - Reserved
5 - Reserved
6 - Reserved
7 - Reserved
CHN Channel enum 0 - Channel 1
1 - Channel 2
2 - Channel 3
3 - Channel 4
CMD Command Id enum 0-5 - Command ID {value}
D2-05-02 (Type 0x02)
command: 1
shortcut description type values
POS Vertical position enum 0-100 - Output position {value}%
127 - Do not change
ANG Rotation angle enum 0-100 - Output angle {value}%
127 - Do not change
REPO Repositioning enum 0 - Go directly to POS/ANG
1 - Go up (0%), then to POS/ANG
2 - Go down (100%), then to POS/ANG
3 - Reserved
LOCK Locking modes enum 0 - Do not change
1 - Set blockage mode
2 - Reserved
3 - Reserved
4 - Reserved
5 - Reserved
6 - Reserved
7 - Deblockage
CHN Channel enum 0 - Channel 1
1-15 - Reserved {value}
CMD Command Id enum 0 - Reserved
1-4 - Command ID {value}
5-15 - Reserved {value}
command: 2
shortcut description type values
CHN Channel enum 0 - Channel 1
1-15 - Reserved {value}
CMD Command Id enum 0 - Reserved
1-4 - Command ID {value}
5-15 - Reserved {value}
command: 3
shortcut description type values
CHN Channel enum 0 - Channel 1
1-15 - Reserved {value}
CMD Command Id enum 0 - Reserved
1-4 - Command ID {value}
5-15 - Reserved {value}
command: 4
shortcut description type values
POS Current vertical position enum 0-100 - Output position {value}%
127 - Position unknown, will be known after the next goto cmd
ANG Current rotation angle enum 0-100 - Output angle {value}%
127 - Angle unknown, will be known after the next goto cmd
LOCK Current locking mode enum 0 - Normal (no lock)
1 - Blockage mode
2 - Reserved
3 - Reserved
4 - Reserved
5 - Reserved
6 - Reserved
7 - Reserved
CHN Channel enum 0 - Channel 1
1-15 - Reserved {value}
CMD Command Id enum 0 - Reserved
1-4 - Command ID {value}
5-15 - Reserved {value}
14 (Multi Function Sensors)
D2-14-30 (Sensor for Smoke, Air quality, Hygrothermal comfort, Temperature and Humidity)
shortcut description type values
SMA0 Smoke Alarm status enum 0 - Smoke Alarm non-activated
1 - Smoke Alarm activated
SMA1 Sensor fault mode status enum 0 - Sensor Fault mode non-activated
1 - Sensor Fault mode activated
SMA2 Smoke Alarm Condition analysis: Maintenance enum 0 - Maintenance OK
1 - Maintenance not done
SMA3 Smoke Alarm Condition analysis: Humidity enum 0 - Humidity range OK
1 - Humidity range NOK
SMA4 Smoke Alarm Condition analysis: Temperature enum 0 - Temperature range OK
1 - Temperature range NOK
SMA5 Time since last maintenance enum 0-250 - {value} week(s)
251-254 - Reserved
255 - Error
ES Energy Storage Status enum 0 - High
1 - Medium
2 - Low
3 - Critical
RPLT Countdown time until product end of life enum 0-120 - {value} month(s)
121-254 - Reserved
255 - Error
TMP8 Temperature value 0.0-250.0 ↔ 0.0-50.0 °C
HUM Humidity value 0.0-200.0 ↔ 0.0-100.0 %
HCI Hygrothermal Comfort Index enum 0 - Good
1 - Medium
2 - Bad
3 - Error
IAQTH T/Hum. Indoor Air Analysis enum 0 - Optimal air range
1 - Dry Air range
2 - High humidity range
3 - High temperature and humidity range
4 - Temperature or Humidity out of analysis range
5-6 - Reserved
7 - Error
D2-14-41 (Indoor -Temperature, Humidity XYZ Acceleration, Illumination Sensor)
shortcut description type values
TMP Temperature 10 value 0.0-1000.0 ↔ -40.0-60.0 °C
HUM Rel. Humidity (linear) value 0.0-200.0 ↔ 0.0-100.0 %
ILL Illumination (linear) value 0.0-100000.0 ↔ 0.0-100000.0 lx
ACC Acceleration Status enum 0 - Periodic Update
1 - Threshold 1 exceeded
2 - Threshold 2 exceeded
ACX Absolute Acceleration on X axis value 0.0-1000.0 ↔ -2.5-2.5 g
ACY Absolute Acceleration on Y axis value 0.0-1000.0 ↔ -2.5-2.5 g
ACZ Absolute Acceleration on Z axis value 0.0-1000.0 ↔ -2.5-2.5 g
CO Contact enum 0 - Open
1 - Closed
50 (Heat Recovery Ventilation)
D2-50-00 (Type 0x00 (single room ventilation unit))
command: 0
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
RMT Requested Message Type enum 0 - Ventilation basic status
1 - Ventilation extended status
command: 1
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
DOMC Direct Operation Mode Control enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - No action (keep current ventilation mode/level)
OMC Operation Mode Control enum 0 - No action
1 - Select next operation mode (edge-trigger)
2 - Select previous operation mode (edge-trigger)
3 - Reserved
TOMC Timer Operation Mode Control enum 0 - No action
1 - Start timer operation mode (edge-trigger)
COT CO2 Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
HT Humidity Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
AQT Air Quality Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
command: 2
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
OMS Operation Mode Status enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - Reserved
SFP Supply Air Flap Position enum 0 - Supply air flap closed
1 - Supply air flap opened
EFP Exhaust Air Flap Position enum 0 - Exhaust air flap closed
1 - Exhaust air flap opened
DMS Defrost Mode Status enum 0 - Defrost mode inactive
1 - Defrost mode active
CPS Cooling Protection Status enum 0 - Cooling protection mode inactive
1 - Cooling protection mode active
DHS Drain Heater Status enum 0 - Inactive
1 - Active
TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive
1 - timer operation mode active
FMS Filter Maintenance Status enum 0 - Maintenance not required
1 - Maintenance required
AQS1 Air Quality Sensor 1 enum 0-100 - {value} %
101-126 - Reserved
127 - Not available
MSS Master/Slave Configuration Status enum 0 - Master
1 - Slave
OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
command: 3
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0
OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0
IMS Info Message 0...15 Status enum 0-65535 - {value}
FS Fault 0...31 Status enum 0-4294967295 - {value}
D2-50-01 (Type 0x01 (single room ventilation unit with pre-heater))
command: 0
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
RMT Requested Message Type enum 0 - Ventilation basic status
1 - Ventilation extended status
command: 1
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
DOMC Direct Operation Mode Control enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - No action (keep current ventilation mode/level)
OMC Operation Mode Control enum 0 - No action
1 - Select next operation mode (edge-trigger)
2 - Select previous operation mode (edge-trigger)
3 - Reserved
TOMC Timer Operation Mode Control enum 0 - No action
1 - Start timer operation mode (edge-trigger)
COT CO2 Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
HT Humidity Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
AQT Air Quality Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
command: 2
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
OMS Operation Mode Status enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - Reserved
SFP Supply Air Flap Position enum 0 - Supply air flap closed
1 - Supply air flap opened
EFP Exhaust Air Flap Position enum 0 - Exhaust air flap closed
1 - Exhaust air flap opened
DMS Defrost Mode Status enum 0 - Defrost mode inactive
1 - Defrost mode active
CPS Cooling Protection Status enum 0 - Cooling protection mode inactive
1 - Cooling protection mode active
OHS Outdoor Air Heater Status enum 0 - Inactive
1 - Active
DHS Drain Heater Status enum 0 - Inactive
1 - Active
TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive
1 - timer operation mode active
FMS Filter Maintenance Status enum 0 - Maintenance not required
1 - Maintenance required
AQS1 Air Quality Sensor 1 enum 0-100 - {value} %
101-126 - Reserved
127 - Not available
MSS Master/Slave Configuration Status enum 0 - Master
1 - Slave
OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
command: 3
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0
OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0
IMS Info Message 0...15 Status enum 0-65535 - {value}
FS Fault 0...31 Status enum 0-4294967295 - {value}
D2-50-10 (Type 0x10 (multi room ventilation unit without bypass))
command: 0
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
RMT Requested Message Type enum 0 - Ventilation basic status
1 - Ventilation extended status
command: 1
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
DOMC Direct Operation Mode Control enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - No action (keep current ventilation mode/level)
OMC Operation Mode Control enum 0 - No action
1 - Select next operation mode (edge-trigger)
2 - Select previous operation mode (edge-trigger)
3 - Reserved
TOMC Timer Operation Mode Control enum 0 - No action
1 - Start timer operation mode (edge-trigger)
COT CO2 Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
HT Humidity Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
AQT Air Quality Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
RTT Room temperature threshold value 1.0-127.0 ↔ -63.0-63.0 °C
command: 2
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
OMS Operation Mode Status enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - Reserved
DMS Defrost Mode Status enum 0 - Defrost mode inactive
1 - Defrost mode active
CPS Cooling Protection Status enum 0 - Cooling protection mode inactive
1 - Cooling protection mode active
OHS Outdoor Air Heater Status enum 0 - Inactive
1 - Active
SHS Supply Air Heater Status enum 0 - Inactive
1 - Active
TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive
1 - timer operation mode active
FMS Filter Maintenance Status enum 0 - Maintenance not required
1 - Maintenance required
WTPS Weekly Timer Program Status enum 0 - Weekly timer program disabled or not configured
1 - Weekly timer program active
RTCS Room Temperature Control Status enum 0 - Room temperature control inactive
1 - Room temperature control active
AQS1 Air Quality Sensor 1 enum 0-100 - {value} %
101-126 - Reserved
127 - Not available
AQS2 Air Quality Sensor 2 enum 0-100 - {value} %
101-126 - Reserved
127 - Not available
OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
INT Indoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
EXHT Exhaust Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
command: 3
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0
OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0
DIS Digital Input 0...15 Status enum 0-65535 - {value}
DOS Digital Output 0...15 Status enum 0-65535 - {value}
IMS Info Message 0...15 Status enum 0-65535 - {value}
FS Fault 0...31 Status enum 0-4294967295 - {value}
D2-50-11 (Type 0x11 (multi room ventilation unit with bypass))
command: 0
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
RMT Requested Message Type enum 0 - Ventilation basic status
1 - Ventilation extended status
command: 1
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
DOMC Direct Operation Mode Control enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - No action (keep current ventilation mode/level)
OMC Operation Mode Control enum 0 - No action
1 - Select next operation mode (edge-trigger)
2 - Select previous operation mode (edge-trigger)
3 - Reserved
HBC Heat Exchanger Bypass Control enum 0 - No action
1 - Close bypass (edge-trigger)
2 - Open bypass (edge-trigger)
3 - Reserved
TOMC Timer Operation Mode Control enum 0 - No action
1 - Start timer operation mode (edge-trigger)
COT CO2 Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
HT Humidity Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
AQT Air Quality Threshold enum 0-100 - {value} %
101-126 - Reserved
127 - Default (use threshold configured in device)
RTT Room temperature threshold value 1.0-127.0 ↔ -63.0-63.0 °C
command: 2
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
OMS Operation Mode Status enum 0 - Off
1 - Level 1
2 - Level 2
3 - Level 3
4 - Level 4
5-10 - Reserved
11 - Automatic
12 - Automatic on demand
13 - Supply air only
14 - Exhaust air only
15 - Reserved
SMS Safety Mode Status enum 0 - Fireplace safety mode disabled
1 - Fireplace safety mode enabled
HBS Heat Exchanger Bypass Status enum 0 - Bypass closed (heat-recovery active)
1 - Bypass opened (heat-recovery inactive)
DMS Defrost Mode Status enum 0 - Defrost mode inactive
1 - Defrost mode active
CPS Cooling Protection Status enum 0 - Cooling protection mode inactive
1 - Cooling protection mode active
OHS Outdoor Air Heater Status enum 0 - Inactive
1 - Active
SHS Supply Air Heater Status enum 0 - Inactive
1 - Active
TOMS Timer Operation Mode Status enum 0 - timer operation mode inactive
1 - timer operation mode active
FMS Filter Maintenance Status enum 0 - Maintenance not required
1 - Maintenance required
WTPS Weekly Timer Program Status enum 0 - Weekly timer program disabled or not configured
1 - Weekly timer program active
RTCS Room Temperature Control Status enum 0 - Room temperature control inactive
1 - Room temperature control active
AQS1 Air Quality Sensor 1 enum 0-100 - {value} %
101-126 - Reserved
127 - Not available
AQS2 Air Quality Sensor 2 enum 0-100 - {value} %
101-126 - Reserved
127 - Not available
OUTT Outdoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYT Supply Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
INT Indoor Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
EXHT Exhaust Air Temperature value 0.0-127.0 ↔ -64.0-63.0 °C
SPLYFF Supply Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
EXHFF Exhaust Air Fan Air Flow Rate value 0.0-1023.0 ↔ 0.0-1023.0 m3/h
SPLYFS Supply Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
EXHFS Exhaust Fan Speed value 0.0-4095.0 ↔ 0.0-4095.0 1/min
command: 3
shortcut description type values
MT Message Type enum 0-3 - Message Type {value}
4-7 - Reserved {value}
SVI Software Version Info value 0.0-4095.0 ↔ 0.0-4095.0
OHC Operation Hours Counter value 0.0-65535.0 ↔ 0.0-196605.0
DIS Digital Input 0...15 Status enum 0-65535 - {value}
DOS Digital Output 0...15 Status enum 0-65535 - {value}
IMS Info Message 0...15 Status enum 0-65535 - {value}
FS Fault 0...31 Status enum 0-4294967295 - {value}