A new approach to calculating production and consumption powers that would bypass the problem of identifying where consumption happens in the component graph.
Batteries or meters WITH battery successors(direct or indirect):
-
Their consumption power could be charging power of the battery, so their powers can't be used for the site's consumption power.
-
Their production power could be discharging from batteries, so they can't be used for the site's production power.
-
When such a component is encountered during traversal, if it has other non-battery successors, those should be used to calculate production and consumption powers.
Non-battery components or meters WITHOUT battery successors (direct or indirect):
-
This includes dangling meters, and meters with only other types of successors, other than battery inverters.
-
Production formula should contain a
min(0,meter_power)
component in the formula for each such meter. -
Consumption formula should contain a
max(0,meter_power)
component in the formula for each such meter.
Validation
-
These
min
,max
formula components should accept an optional validation check. For example,min(0, meter_power, x >= 0.0)
. Then for each value in the data stream, every time the validation fails, we log a message, but we still use the value. -
The log messages should be rate-limited to upto once a minute or something similar, to prevent spamming.
-
Meters without successors: They are normally assumed to have only consumers, so the production component should have a validation of
x == 0
. Then if we measure production from dangling meters, we will see a log message. -
CHP: They are expected to always produce, so their consumption component should have a validation of
x == 0
. -
PV inverters: They are expected to always produce, but they have small consumption at night. So a simple
x == 0
validation for consumption will not be enough.
When there's a grid meter
-
When there's a grid meter at a site, we would also add an unmetered component to the formulas.
-
This would be calculated by subtracting the powers of all the successors of the grid meter, from the power measured at the grid meter.
-
Production formula should contain a
min(0,unmetered_power, x == 0)
component in the formula for each such meter. -
Consumption formula should contain a
max(0,unmetered_power)
component in the formula for each such meter.