You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
mingw: make isatty() recognize MSYS2's pseudo terminals (/dev/pty*)
MSYS2 emulates pseudo terminals via named pipes, and isatty() returns 0
for such file descriptors. Therefore, some interactive functionality
(such as launching a pager, asking if a failed unlink should be repeated
etc.) doesn't work when run in a terminal emulator that uses MSYS2's
ptys (such as mintty).
However, MSYS2 uses special names for its pty pipes ('msys-*-pty*'),
which allows us to distinguish them from normal piped input / output.
On startup, check if stdin / stdout / stderr are connected to such pipes
using the NtQueryObject API from NTDll.dll. If the names match, adjust
the flags in MSVCRT's ioinfo structure accordingly.
Signed-off-by: Karsten Blees <[email protected]>
Signed-off-by: Johannes Schindelin <[email protected]>
Signed-off-by: Junio C Hamano <[email protected]>
0 commit comments