X Axis Flip Still Needed? #3

@mdicicco

Description

@mdicicco

Is it still true that ATI sensors don't use the right hand rule for their sensor axes? I have a new Axia80 and it seems to be correct (i.e. it uses a right hand coord system). The raw netft_data seems to match up with the +X and +Y labels on the sensor and the +Z data lines up with a right hand rule. The flip on lines 244/247 of netft_utils seems to be unnecessary.

I did a quick scan of the ATI website and first two sensor drawings in their pdf (the nano17 and then the nano17e) both use a right hand rule as well, although I don't have any other sensors to test on.

I modified my local copy but it could be a good thing to either note or put in a config to disable.