Notifications
You must be signed in to change notification settings - Fork 24
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
--- Tinker-HP : detected abnormal fluctuation on energy #24
Comments
Hi, Louis |
Thanks for your suggestion.However, it reported different error after I changed the barostat:
This means a lack of memory? |
It is most probably just an indirect consequence of an "MD explosion" that may be due to an issue with the parameters. |
Thanks for your reply, I check the parameters. |
Besides, When I use montecarlo barostat, the box become longer and narrower. Is there any keyword to adjust the isotropy of pressure? |
When I run NPT ensemble in tinker-hp, it reported this error:
This is my input file:
the command:
Because my system includes two organic molecules, I add some new parameters generated by poltype2. Maybe error parameters?
The text was updated successfully, but these errors were encountered: