Misc Attributes

(MiscAttributes.cs)

[DataType]

The following table shows how the IEC 61131-3 data types are mapped to the .NET-Framework and to C#, respectively. Variables of data types that are marked in the column "DataType Attribute" with a '+' must have the optional attribute "DataType" for an unambiguous assignment.

IEC 61131-3 .NET Framework C# DataType Attribute
BOOL System.Boolean bool -
SINT System.SByte sbyte -
INT System.Int16 short -
DINT System.Int32 int -
LINT System.Int64 long -
USINT System.Byte byte -
UINT System.UInt16 ushort -
UDINT System.UInt32 uint -
ULINT System.UInt64 ulong -
REAL System.Single float -
LREAL System.Double double -
TIME System.UInt32 uint +
LTIME System.Int64 long +
LDATE System.Int64 long +
LTOD System.Int64 long +
LDT System.Int64 long +
BYTE System.Byte byte +
WORD System.UInt16 ushort +
DWORD System.UInt32 uint +
LWORD System.UInt64 ulong +
STRING System.Iec61131Lib.IecStringEx -
ANY System.Iec61131Lib.Any +
ANY_MAGNITUDE System.Iec61131Lib.Any +
ANY_NUM System.Iec61131Lib.Any +
ANY_INT System.Iec61131Lib.Any +
ANY_SIGNED System.Iec61131Lib.Any +
ANY_UNSIGNED System.Iec61131Lib.Any +
ANY_REAL System.Iec61131Lib.Any +
ANY_BIT System.Iec61131Lib.Any +
ANY_ELEMENTARY System.Iec61131Lib.Any +

[OPC]

PLCnext has an integrated OPC server. The [OPC] attribute adds the related field as a new entry in the server tree, under the root entry ARP.Eclr.

[Ehmi]

The port/variable is visible for the local Web Server and can be read and written via the REST interface.

[ProfiCloud]

The port/variable is visible for Proficloud services and can therefore be subscribed by Proficloud devices.

[Redundant]

This attribute is only relevant for PLCnext Technology controllers with redundancy function. It enables the synchronization of variables and ports between the PRIMARY and BACKUP controller. The PRIMARY controller transfers the value to be synchronized to the BACKUP controller before each cycle.

[Retain]

This attribute allowes fields of classes attributed with [Program] or [FunctionBlock] to be kept during power down so these values can be restored on power return. For more information you can read about retain handling in the PLCnext Info Center. Alternatively, the GdsRetain attribute can be used, but it is not allowed to mix GdsRetain and Retain within the POU.

[Local]

This attribute on public FB fields exposes that field to the user in IEC code worksheets. The field is accessible through the FB instance.


For the following attributes are defined in the Iec61131.Engineering.Prototypes.Pragmas. The according include is set since PLCnext toolchain version 2023.0 and need to be added in older projects manually.

[Hidden]

This attribute hides user defined data types (arrays, structures, enumerations, strings) and program organization units (functions, function blocks, programs) from Type Hierarchy and IntelliSense.

[NotOverridable]

It is possible to override program organization units in a PLCnext Engineer project to change their functionality. The [NotOverridable] attribute can be used to prevent this for specific POUs. It is possible to override program organization units written in C# with a POU of the same name and parameters in PLCnext Engineer. Use case is to modify functionality without having access to the sources of the library; e.g. in a maintenance test environment. The NotOverridable attribute can be used to prevent the POU from beeing overridden inside PLCnext Engineer.

[Invisible]

This attribute added to inputs and outputs of function blocks hides the pin on graphical editors in the PLCnext Engineer. Direct access is still possible.