On DC mode, when we set limit lower than current battery percent,
EC will fail to set ctrl_mode.
That cause function fail, we will keep charge when plug AC.
TEST=AC+DC set higher and lower limit, DC set higher and lower limit.
Unit can charge and discharge to limit, and stop at limit.