1-
# Adding The SCD40 CO2 Sensor To The AIR-1 (Original Design)
1+
# Adding The SCD40 CO<sub>2</sub> Sensor To The AIR-1 (Original Design)
22

33
1\. Unplug your AIR-1 from power and remove the back
44

55
![IMG_3790.jpeg](../assets/img-3790.jpeg)
66

77
2\. At the bottom center there is a black connector. There is an x in the lower right corner of the connector
88

9-
3\. Orientate the CO2 module so the white x on the module is also in the lower right and the gold dot is in the upper left as seen below
9+
3\. Orientate the CO<sub>2</sub> module so the white x on the module is also in the lower right and the gold dot is in the upper left as seen below
1010

11-
4\. Align the connector on the back of the CO2 module with the connector on the AIR-1. Once aligned, push down so the CO2 module fully seats itself
11+
4\. Align the connector on the back of the CO<sub>2</sub> module with the connector on the AIR-1. Once aligned, push down so the CO<sub>2</sub> module fully seats itself
1212

1313
![IMG_3791.jpeg](../assets/img-3791.jpeg)
1414

15-
5\. Put your AIR-1 cover on. Please refer to our [CO2 calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO2 module.
15+
5\. Put your AIR-1 cover on. Please refer to our [CO<sub>2</sub> calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO<sub>2</sub> module.

docs/products/air1/addons/adding-co2-to-air-1.md

+4-4
Original file line numberDiff line numberDiff line change
@@ -1,4 +1,4 @@
1-
# Adding CO2 to AIR-1
1+
# Adding CO<sub>2</sub> to AIR-1
22

33
!!! tip "Tip"
44

@@ -20,11 +20,11 @@
2020

2121
![](../../../assets/air-1-add-co2-pic-6.jpg)![](../../../assets/air-1-add-co2-pic-7.jpg)
2222

23-
5\. Flip the PCB over and identify the bottom right corner where the small black mezzanine connector lives. You will see an "X" indicating which corner needs to be lined up with the SCD40 CO2 sensor. There is an X on the SCD40 sensor's PCB as well, you can see it in the image below but it is slightly cut off on the PCB itself. There is also a "gold dot" in the top left of the SCD40 when oriented properly.
23+
5\. Flip the PCB over and identify the bottom right corner where the small black mezzanine connector lives. You will see an "X" indicating which corner needs to be lined up with the SCD40 CO<sub>2</sub> sensor. There is an X on the SCD40 sensor's PCB as well, you can see it in the image below but it is slightly cut off on the PCB itself. There is also a "gold dot" in the top left of the SCD40 when oriented properly.
2424

2525
![](../../../assets/air-1-add-co2-pic-8.jpg)
2626

27-
6\. Gently push the SCD40 CO2 module onto the black mezzanine connector.
27+
6\. Gently push the SCD40 CO<sub>2</sub> module onto the black mezzanine connector.
2828

2929
![](../../../assets/air-1-add-co2-pic-9-1.jpg)
3030

@@ -36,4 +36,4 @@
3636

3737
![](../../../assets/air-1-add-co2-pic-12.jpg)![](../../../assets/air-1-add-co2-pic-13.jpg)![](../../../assets/air-1-add-co2-pic-14.jpg)
3838

39-
9\. Please refer to our [CO2 calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO2 module after installation. This is required for all CO2 addons purchased from us separately from a product (such as buying it to addon to an existing Apollo device).
39+
9\. Please refer to our [CO<sub>2</sub> calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO<sub>2</sub> module after installation. This is required for all CO<sub>2</sub> addons purchased from us separately from a product (such as buying it to addon to an existing Apollo device).
Original file line numberDiff line numberDiff line change
@@ -1,4 +1,4 @@
1-
# Adding CO2 To MSR-1
1+
# Adding CO<sub>2</sub> To MSR-1
22

33
1\. Unplug your MSR-1 from power and remove the back
44

@@ -8,12 +8,12 @@
88

99
![IMG_3788.jpeg](../assets/img-3788.jpeg)
1010

11-
3\. Orientate the CO2 module so the white x on the module is also in the lower right and the gold dot is in the upper left as seen below
11+
3\. Orientate the CO<sub>2</sub> module so the white x on the module is also in the lower right and the gold dot is in the upper left as seen below
1212

1313
![IMG_3787.jpeg](../assets/img-3787.jpeg)
1414

15-
4\. Align the connector on the back of the CO2 module with the connector on the MSR-1. Once aligned, push down so the CO2 module fully seats itself
15+
4\. Align the connector on the back of the CO<sub>2</sub> module with the connector on the MSR-1. Once aligned, push down so the CO<sub>2</sub> module fully seats itself
1616

1717
![IMG_3789.jpeg](../assets/img-3789.jpeg)
1818

19-
5\. Put your MSR-1 back in the case and slide the back cover on. Please refer to our [CO2 calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO2 module.
19+
5\. Put your MSR-1 back in the case and slide the back cover on. Please refer to our [CO<sub>2</sub> calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO<sub>2</sub> module.

docs/products/msr2/addons/adding-co2-to-msr-2.md

+4-4
Original file line numberDiff line numberDiff line change
@@ -1,4 +1,4 @@
1-
# Adding CO2 To MSR-2
1+
# Adding CO<sub>2</sub> To MSR-2
22

33
1\. Unplug your MSR-2 from power and remove the back
44

@@ -8,11 +8,11 @@
88

99
![](../../../assets/msr-2-add-co2-pic-4.jpg)![](../../../assets/msr-2-add-co2-pic-5.jpg)![](../../../assets/msr-2-add-co2-pic-6.jpg)
1010

11-
3\. With the case removed, identify the bottom right corner where the small black mezzanine connector lives. You will see an "X" indicating which corner needs to be lined up with the SCD40 CO2 sensor. There is an X on the SCD40 sensor's PCB as well, you can see it in the image below but it is slightly cut off on the PCB itself. There is also a "gold dot" in the top left of the SCD40 when oriented properly.
11+
3\. With the case removed, identify the bottom right corner where the small black mezzanine connector lives. You will see an "X" indicating which corner needs to be lined up with the SCD40 CO<sub>2</sub> sensor. There is an X on the SCD40 sensor's PCB as well, you can see it in the image below but it is slightly cut off on the PCB itself. There is also a "gold dot" in the top left of the SCD40 when oriented properly.
1212

1313
![](../../../assets/msr-2-add-co2-pic-7.jpg)![](../../../assets/msr-2-add-co2-pic-8.jpg)
1414

15-
4\. Gently push the SCD40 CO2 module onto the black mezzanine connector.
15+
4\. Gently push the SCD40 CO<sub>2</sub> module onto the black mezzanine connector.
1616

1717
![](../../../assets/msr-2-add-co2-pic-9.jpg)![](../../../assets/msr-2-add-co2-pic-10.jpg)
1818

@@ -24,4 +24,4 @@
2424

2525
![](../../../assets/msr-2-add-co2-pic-15.jpg)
2626

27-
7\. Please refer to our [CO2 calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO2 module after installation. This is required for all CO2 addons purchased from us separately from a product (such as buying it to addon to an existing Apollo device).
27+
7\. Please refer to our [CO<sub>2</sub> calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO<sub>2</sub> module after installation. This is required for all CO<sub>2</sub> addons purchased from us separately from a product (such as buying it to addon to an existing Apollo device).

docs/products/mtr1/addons/adding-co2-to-mtr-1.md

+4-4
Original file line numberDiff line numberDiff line change
@@ -1,4 +1,4 @@
1-
# Adding CO2 To MTR-1
1+
# Adding CO<sub>2</sub> To MTR-1
22

33
1\. Unplug your MTR-1 from power and remove the stand if attached.
44

@@ -8,11 +8,11 @@
88

99
![](../../../assets/mtr-1-add-co2-pic-5.jpg)
1010

11-
3\. With the case removed, identify the bottom right corner of where the small black mezzanine connector lives. You will see an "X" indicating which corner needs to be lined up with the SCD40 CO2 sensor. There is an X on the SCD40 sensor's PCB as well, you can see it in the image below. There is also a "gold dot" in the top left of the SCD40 when oriented properly.
11+
3\. With the case removed, identify the bottom right corner of where the small black mezzanine connector lives. You will see an "X" indicating which corner needs to be lined up with the SCD40 CO<sub>2</sub> sensor. There is an X on the SCD40 sensor's PCB as well, you can see it in the image below. There is also a "gold dot" in the top left of the SCD40 when oriented properly.
1212

1313
![](../../../assets/mtr-1-add-co2-pic-6.jpg)![](../../../assets/mtr-1-add-co2-pic-7.jpg)
1414

15-
4\. Gently push the SCD40 CO2 module onto the black mezzanine connector.
15+
4\. Gently push the SCD40 CO<sub>2</sub> module onto the black mezzanine connector.
1616

1717
![](../../../assets/mtr-1-add-co2-pic-8.jpg)![](../../../assets/mtr-1-add-co2-pic-9.jpg)
1818

@@ -32,4 +32,4 @@
3232

3333
![](../../../assets/mtr-1-add-co2-pic-14.jpg)
3434

35-
9\. Please refer to our [CO2 calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO2 module after installation. This is required for all CO2 addons purchased from us separately from a product (such as buying it to addon to an existing Apollo device).
35+
9\. Please refer to our [CO<sub>2</sub> calibration guide](https://wiki.apolloautomation.com/products/general/calibrating-and-updating/co2-calibration/ "CO2 Calibration") to calibrate the CO<sub>2</sub> module after installation. This is required for all CO<sub>2</sub> addons purchased from us separately from a product (such as buying it to addon to an existing Apollo device).

0 commit comments

Comments
 (0)